Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2017-01-25-7

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 7427
DEA: 07215934
EFIS: 0700001833
DIST-CO-RTE-PM07-LA-5-2.4/4.0
Award Date08/14/2012
Closeout Date02/20/2020
Work DescriptionWiden and Realign Freeway and Construct Ped OC, OC and UC Structures.
Location DescriptionLOS ANGELES COUNTY IN SANTA FE SPRINGS AND NORWALK FROM 0.1 MILE NORTH OF CARMENITA ROAD OVERCROSSING TO 0.1 MILE NORTH OF SILVERBOW AVENUE PEDESTRIAN OVERCROSSING
QA Service Level1 (Verified on 11/26/2012)

Sample Information

Sample Taken Date01/25/2017 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/31/2017
Sample typeQuality Assurance A brief description of the sampleA615 Grade 75 Threaded Bar
The quantity of what the sample constitutes2 From where was the sample collectedJob Site
First name of sampler or witnessed byBahjat Last name of sampler or witnessed byDagher
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameWilliams Transportation Laboratory (TL) NumberC953153
Inspector Lot Number from the Transportation Laboratory (TL) FormL9300117 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingProduction Testing
Threaded Bar SpecificationASTM A615 Threaded Bar Grade75
Threaded Bar TypeDeformed Rebar Size#10
Nut Specification for Threaded BarA615 System ManufacturerWilliams Form
Epoxy Coating ColorNA Threaded Bar ApplicationSoil Nail
Coating StandardsUncoated Bar Heat Number(s)PL16107210
Nut Heat Number(s)5173645 Bar Lot NumberN/A
Nut Lot Number10H5D Coupler Heat Number(s)N/A
Coupler GradeN/A

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2017-01-25-7-1ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory02/03/2017Fred
Yes
02/10/2017A615 Bar & Nut
2017-01-25-7-2ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory02/03/2017Fred
Yes
02/10/2017A615 Bar & Nut
2017-01-25-7-3ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)Glen Weldon, CT HQ - Sacramento Structural Materials Testing Laboratory02/01/2017Glen Weldon
Yes
02/10/2017

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2017-01-25-7-1 ASTM A615-15 (Verified)
DIME Test ID: 2017-01-25-7-2 ASTM A615-15 (Verified)
DIME Test ID: 2017-01-25-7-3 ASTM A934-13 (Verified)