Project Information

Project IdentifiersProject ID: 993333
DEA: 04264724
EFIS: 0419000068
DIST-CO-RTE-PM04-MRN-101-R20.8/27.1
Award Date04/26/2022
Closeout DateNot set
Work DescriptionCIP BRIDGES, CONSTRUCT ROADWAY, RETAINING WALLS AND MODIFY ELECTRICAL.
Location DescriptionMARIN COUNTY IN AND NEAR NOVATO FROM 0.1 MILE SOUTH OF FRANKLIN AVENUE OVERHEAD TO 0.5 MILE SOUTH OF SAN ANTONIO CREEK BRIDGE
QA Service Level1 (Verified on 11/01/2021)

Sample Information

Sample Taken Date09/05/2024 Sample Unique Key87
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/05/2024
Sample typeQuality Assurance A brief description of the sample3 4x8 concrete cylinders
The quantity of what the sample constitutes27CY From where was the sample collectedJob Site
First name of sampler or witnessed byMario Last name of sampler or witnessed byVital
Title of samplerASR Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameShamrock Materials Inc Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameDS40 & DS69 WW Footing

Material Information

Material TypeConcrete The concrete mix design numberSL4201CG
The truck number from where the sample was collected2454 The batch plant ticket number from where the sample was collected292286
Concrete batch plant138 The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedCHUTE FROM TRUCK Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-09-05-87-1ASTM C1064-08: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement ConcreteMario Vital, CT SC - 3672 - Novato09/05/2024Josh Velono
Yes
09/19/2024
2024-09-05-87-2ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement ConcreteMario Vital, CT SC - 3672 - Novato09/05/2024Josh Velono
Yes
09/19/2024
2024-09-05-87-3ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensSA, CT HQ - Sacramento Concrete Testing Laboratory10/03/2024SA
Yes
10/03/2024

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-09-05-87-1 ASTM C1064-08 (Verified)
DIME Test ID: 2024-09-05-87-2 ASTM C143-20 (Verified)
DIME Test ID: 2024-09-05-87-3 ASTM C39-17a (Verified)