Sample Record

Owner Lab

  • CT D04 - Concord Field Laboratory

DIME Sample ID 2024-09-08-27

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 1000251
DEA: 042Y5004
EFIS: 0423000122
DIST-CO-RTE-PM04-NAP-221-0.2/1.7
Award Date06/12/2024
Closeout DateNot set
Work DescriptionCOLD PLANE ASPHALT CONCRETE PAVEMENT AND OVERLAY WITH RHMA-G.
Location DescriptionNAPA COUNTY IN AND NEAR NAPA FROM 0.2 MILE NORTH OF JUNCTION ROUTE 12/29 TO 0.2 MILE NORTH OF BASALT ROAD UNDERCROSSING
QA Service Level1 (Verified on 06/03/2024)

Sample Information

Sample Taken Date09/08/2024 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/10/2024
Sample typeQuality Assurance A brief description of the sample1/2"RHMA-G
The quantity of what the sample constitutes0-750 Tons From where was the sample collectedSource
First name of sampler or witnessed byJacob Last name of sampler or witnessed byVega
Title of samplerLab Technician Telephone number of sampler8316826277
Laboratory sample identificationCon_24_678 Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert Woodland Batch Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number1
Sublot number1 HMA Mix Number30640542508P

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-09-08-27-1AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)Jacob Vega, CT D04 - Concord Field Laboratory09/10/2024Jacob Vega
Yes
09/16/2024Teichert Woodland batch Plant Theoretical maximum density at 25°C (77°F)=2460.3
2024-09-08-27-2AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)Jacob Vega, CT D04 - Concord Field Laboratory09/13/2024Jacob Vega
Yes
09/16/2024Teichert Woodland Batch Plant
2024-09-08-27-3AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)Jacob Vega, CT D04 - Concord Field Laboratory09/13/2024Jacob Vega
Yes
09/16/2024LOT 1 SUBLOT 1 Teichert Woodland batch Plant
2024-09-08-27-4AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)Jacob Vega, CT D04 - Concord Field Laboratory09/12/2024Jacob Vega
Yes
09/16/2024Teichert Woodland Batch Plant

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-09-08-27-1 AASHTO T209-22 (Verified)
DIME Test ID: 2024-09-08-27-2 AASHTO T269-14 (Verified)
DIME Test ID: 2024-09-08-27-3 AASHTO T275-07r12 (Verified)