Print Report | Back to Sample Detail

Sample Record for 2017-01-09-7

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 210735 DEA: 071193U4 EFIS: 0713000007 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-10-37.2/42.4
Work Description: CONSTRUCT HOV LANES, WIDEN BRIDGES, AND REALIGN RAMPS.
Location Description: IN LA COUNTY FROM CITRUS STREET IN WEST COVINA TO ROUTE 57 IN POMONA
Contractor Name: Guy F. Atkinson
Contractor Address: 18201 Von Karman Ave, Suite #800, IRVINE CA 92612
Resident Engineer: Rodolfo Cao Structure Rep.: David Win

Sample Information

DIME Sample ID: 2017-01-09-7
TL Number from the TL Form: C940286
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 01/09/2017
Date that the sample was received by the laboratory/organization performing the testing: 01/11/2017
The quantity of what the sample constitutes: 2
A brief description of the sample: A615 Grade 75 Threaded Bar
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: DSI Gerdau

Material Information

Production or Authorization Testing: Production Testing
Threaded Bar Specification: ASTM A615
Threaded Bar Grade: 75
Threaded Bar Type: Deformed
Rebar Size: 8
Nut Specification for Threaded Bar: A519
System Manufacturer: DSI
Epoxy Coating Color: NA
Threaded Bar Application: Threaded Bar
Coating Standards: Uncoated
Bar Heat Number(s): 6214184902
Nut Heat Number(s): 00A152736
Bar Lot Number: Unknown
Nut Lot Number: Unknown
Coupler Heat Number(s): Unknown
Coupler Grade: Unknown

Test Results

Test 1 of 2

DIME Test ID: 2017-01-09-7-1
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 01/12/2017
Date Tested: 01/12/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A615 Threaded Bar and Nut
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
1#8 Bar Heat #6214184902, Nut Heat #00A152736L67-007-170.791112197887215.3A615 Threaded Bar and NutBrian
Temperature 72 F
UTM 400KIP

Test 2 of 2

DIME Test ID: 2017-01-09-7-2
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 01/12/2017
Date Tested: 01/12/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A615 Threaded Bar and Nut
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
2#8 Bar Heat #6214184902, Nut Heat #00A152736L67-007-170.79111332790530A615 Threaded Bar and NutBrian
Temperature 72 F
UTM 400KIP