Print Report | Back to Sample Detail

Sample Record for 2024-09-10-7

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000165 DEA: 09392504 EFIS: 0923000029 QA Service Level: 1
DIST-CO-RTE-PM: 09-INY-395-R17.2/25.8
Work Description: HOT MIX ASPHALT (TYPE A), SHOULDER BACKING, & STRIPING.
Location Description: INYO COUNTY ABOUT 9 MILES SOUTH OF OLANCHA FROM 0.8 MILE SOUTH OF SYKES ROAD TO 0.3 MILE NORTH OF HAIWEE CANYON ROAD
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 8999 Capacity Street, Arvin, CA 93203
Resident Engineer: Garret Rottner Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-09-10-7
TL Number from the TL Form:
Sample Submitted By Organization: CT D09 - Bishop Field Laboratory
Sample Organization Contact: (760) 872-5211
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 09/10/2024
Date that the sample was received by the laboratory/organization performing the testing: 09/10/2024
The quantity of what the sample constitutes: Up to 750 Tons
A brief description of the sample: HMA17
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Construction Arvin Plant

Material Information

HMA Type: Type A HMA
HMA Grading: 1/2 inch
Lot number: 1
Sublot number: 17
HMA Mix Number:

Test Results

Test 1 of 1

DIME Test ID: 2024-09-10-7-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 09/11/2024
Date Tested: 09/11/2024
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-17
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 4273.2 g
Mass of the specimen and specimen basket assembly prior to ignition 5986.7 g
Mass of HMA Sample prior to ignition 1713.5 g
Corrected Asphalt Binder Content 5.09 %
Mass Loss 93.2 g
Mass of aggregate remaining after ignition 1620.3 g
Correction Factor (Percent by mass of HMA Specimen) 0.35 %
Moisture Content 0.00 %
Temperature Compensation Factor 0.00 %
Test Temperature 538 C