Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994696 DEA: 100Y7704 EFIS: 1015000008
QA Service Level: 1
DIST-CO-RTE-PM: 10-MPA-140-12.0/22.1
Work Description: REPLACE AC SURFACING, PLACE HMA AND RHMA, AND BRIDGE REPAIR.
Location Description: MARIPOSA COUNTY NEAR MARIPOSA FROM 1.3 MILES EAST OF CATHEYS VALLEY PARK TO 0.1 MILE NORTH OF ROUTE 49
Contractor Name: GEORGE REED, INC.
Contractor Address: 140 EMPIRE AVE, MODESTO CA 95354
Resident Engineer: Troy Scheiber Structure Rep.: Unknown
DIME Sample ID: 2024-08-12-48
TL Number from the TL Form: 0Y77207
Sample Submitted By Organization: CT D10 - District 10 Materials Laboratory
Sample Organization Contact: (209) 948-7567
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/12/2024
Date that the sample was received by the laboratory/organization performing the testing: 08/14/2024
The quantity of what the sample constitutes: 2 boxs
A brief description of the sample: 3/4 RHMA-G
From where was the sample collected: Manufacturer
Laboratory sample identification: 24-H-97
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: George Reed - Table Mountain Plant
DIME Test ID: 2024-08-12-48-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/20/2024
Date Tested: 08/15/2024
Submitted By Organization: CT D10 - District 10 Materials Laboratory
Organization Address: 1976 East Dr. Martin Luther King Jr. Boulevard,
Organization City: Stockton
Organization State: CA
Organization Zipcode: 95205
Organization Email: mandeep.dhesi@dot.ca.gov
Organization Phone: (209) 948-7567
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Celsius
|
Test procedure used?
|
Method A
|
Mass of HMA Sample prior to ignition
|
2085.8 g
|
Corrected Asphalt Binder Content
|
7.95 %
|
Mass Loss
|
172.6 g
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.33 %
|
Moisture Content
|
no data0 %
|
Temperature Compensation Factor
|
no data0 %
|
Test Temperature
|
538 C
|