Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994966 DEA: 073255U4 EFIS: 0722000129
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-605-20.2/26
Work Description: INDIVIDUAL SLAB REPLACEMENT, COLD PLANE AC
Location Description: LOS ANGELES COUNTY IN BALDWIN PARK AND IRWINDALE FROM ROUTE 10/605 SEPARATION TO 0.2 MILE NORTH OF ROUTE 210/605 SEPARATION
Contractor Name: Peterson Chase General Engineering
Contractor Address: 16351 Construction Circle West, Irvine, CA 92606
Resident Engineer: Steven Taing Structure Rep.: Unknown
DIME Sample ID: 2024-07-09-126
TL Number from the TL Form:
Sample Submitted By Organization: Alta Vista Solutions - Whittier
Sample Organization Contact: (510) 542-9827
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 07/09/2024
Date that the sample was received by the laboratory/organization performing the testing: 06/29/2024
The quantity of what the sample constitutes: 1 bag
A brief description of the sample: A set of 3 JPCP RSC beams
From where was the sample collected: Source
Laboratory sample identification: 24-1682
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: N/A
The concrete mix design number: CTS-65-EH
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 3
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: wheelbarrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2024-07-09-126-1
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Verified Date: 08/09/2024
Date Tested: 07/09/2024
Submitted By Organization: Alta Vista Solutions - Whittier
Organization Address: 12409 Slauson Avenue, Suite I,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90606
Organization Email: nicholas.hoffmann@oneatlas.com
Organization Phone: (510) 542-9827
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens
|
3
|
Does the testing machine measure load or stress on the beam specimen?
|
Stress
|
Fracture initiates in the tension surface
|
Within the Middle Third of the Span Length
|
Fracture occurred at a capped section
|
No
|
Is a beam dimensional correction factor used?
|
Yes
|
Age of specimen
|
10 days
|
Modulus of rupture
|
660 psi
|
Modulus of rupture average
|
670 psi
|
Modulus of rupture 2
|
690 psi
|
Modulus of rupture 3
|
660 psi
|
DIME Test ID: 2024-07-09-126-2
Test Method: CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement Concrete
Verified Date: 08/09/2024
Date Tested: 06/29/2024
Submitted By Organization: Alta Vista Solutions - Whittier
Organization Address: 12409 Slauson Avenue, Suite I,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90606
Organization Email: nicholas.hoffmann@oneatlas.com
Organization Phone: (510) 542-9827
General Comments for this Test: Log # 24-1681
Test Result Compliance:
Additional Comments When Verified: