Sample Record for 2024-06-08-13

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994966 DEA: 073255U4 EFIS: 0722000129 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-605-20.2/26
Work Description: INDIVIDUAL SLAB REPLACEMENT, COLD PLANE AC
Location Description: LOS ANGELES COUNTY IN BALDWIN PARK AND IRWINDALE FROM ROUTE 10/605 SEPARATION TO 0.2 MILE NORTH OF ROUTE 210/605 SEPARATION
Contractor Name: Peterson Chase General Engineering
Contractor Address: 16351 Construction Circle West, Irvine, CA 92606
Resident Engineer: Steven Taing Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-06-08-13
TL Number from the TL Form:
Sample Submitted By Organization: Alta Vista Solutions - Whittier
Sample Organization Contact: (510) 542-9827
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 06/08/2024
Date that the sample was received by the laboratory/organization performing the testing: 06/08/2024
The quantity of what the sample constitutes: 10 cubic yards
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Source
Laboratory sample identification: 24-1415-1416-1417
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: N/A

Material Information

The concrete mix design number: CTS-30-EHI LCB-RS
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 15
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: wheelbarrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 2

DIME Test ID: 2024-06-08-13-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 08/07/2024
Date Tested: 06/16/2024
Submitted By Organization: Alta Vista Solutions - Whittier
Organization Address: 12409 Slauson Avenue, Suite I,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90606
Organization Email: nicholas.hoffmann@oneatlas.com
Organization Phone: (510) 542-9827
General Comments for this Test: Log #'s - 24/1415-1416-1417
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 6
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 5.95 in
Average diameter of cylinder 2 5.95 in
Average diameter of cylinder 3 5.95 in
Average diameter of cylinder 4 5.95 in
Average diameter of cylinder 5 5.95 in
Average diameter of cylinder 6 5.95 in
Cross sectional area of cylinder 1 27.81 in^2
Cross sectional area of cylinder 2 27.81 in^2
Cross sectional area of cylinder 3 27.81 in^2
Cross sectional area of cylinder 4 27.81 in^2
Cross sectional area of cylinder 5 27.81 in^2
Cross sectional area of cylinder 6 27.81 in^2
Compressive strength (to nearest 10 psi) 2460 psi
Maximum load on cylinder 1 69631 lb
Maximum load on cylinder 2 68403 lb
Maximum load on cylinder 3 66768 lb
Maximum load on cylinder 4 67494 lb
Maximum load on cylinder 5 67992 lb
Maximum load on cylinder 6 69805 lb
Compressive strength of cylinder 1 2503.8 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 2459.7 psi
Compressive strength of cylinder 3 2400.9 psi
Compressive strength of cylinder 4 2427 psi
Compressive strength of cylinder 5 2444.9 psi
Compressive strength of cylinder 6 2510.1 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Type of fracture pattern of cylinder 4 2
Type of fracture pattern of cylinder 5 2
Type of fracture pattern of cylinder 6 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Correction factor for cylinder 4 1
Correction factor for cylinder 5 1
Correction factor for cylinder 6 1
Age of specimen 7 days
Age of specimen in hours no data0 hours

Test 2 of 2

DIME Test ID: 2024-06-08-13-2
Test Method: CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement Concrete
Verified Date: 08/07/2024
Date Tested: 06/08/2024
Submitted By Organization: Alta Vista Solutions - Whittier
Organization Address: 12409 Slauson Avenue, Suite I,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90606
Organization Email: nicholas.hoffmann@oneatlas.com
Organization Phone: (510) 542-9827
General Comments for this Test: Log # - 24-1414
Test Result Compliance:
Additional Comments When Verified:
Temperature 73 F