Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 211237 DEA: 080Q7904 EFIS: 0800020481
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-40-R93.1/94.2
Work Description: REPLACE HOFF WASH BRIDGE (BRIDGE NUMBER 54-0889L/R)
Location Description: SAN BERNARDINO COUNTY FROM 0.3 MILE WEST TO 0.4 MILE EAST OF HOFF WASH BRIDGE
Contractor Name: ORTIZ ENTERPRISES, INC.
Contractor Address: 6 Cushing, Suite 200, Irvine, CA 92618
Resident Engineer: Darcy Davis Structure Rep.: Leonard Romero
DIME Sample ID: 2016-12-06-2
TL Number from the TL Form: 06
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 12/06/2016
Date that the sample was received by the laboratory/organization performing the testing: 12/12/2016
The quantity of what the sample constitutes: 2
A brief description of the sample: 6x12
From where was the sample collected: Job Site
Laboratory sample identification: 953-06
Structure unique identifier: hoff wash br
Structure name: abut 1 and wingwalls
The fabricator/manufacturer/facility name: cemex
The concrete mix design number: 1592266
The truck number from where the sample was collected: 7004
The batch plant ticket number from where the sample was collected: 44461844
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: load 9
Where the material sample would have been placed if not sampled: Unknown
From Lot No.: Unknown
Bag Lot No.: Unknown
DIME Test ID: 2016-12-06-2-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 12/16/2016
Date Tested: 12/16/2016
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
6.00 in
|
Cross sectional area of cylinder 1
|
28.27 in^2
|
Cross sectional area of cylinder 2
|
28.27 in^2
|
Compressive strength (to nearest 10 psi)
|
3970 psi
|
Maximum load on cylinder 1
|
113190 lb
|
Maximum load on cylinder 2
|
111510 lb
|
Compressive strength of cylinder 1
|
4003.9 psi
|
Type of fracture pattern of cylinder 1
|
2
|
Compressive strength of cylinder 2
|
3944.5 psi
|
Type of fracture pattern of cylinder 2
|
2
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
no data
|
Age of specimen
|
10 days
|
Age of specimen in hours
|
no data
|