Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 211237 DEA: 080Q7904 EFIS: 0800020481
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-40-R93.1/94.2
Work Description: REPLACE HOFF WASH BRIDGE (BRIDGE NUMBER 54-0889L/R)
Location Description: SAN BERNARDINO COUNTY FROM 0.3 MILE WEST TO 0.4 MILE EAST OF HOFF WASH BRIDGE
Contractor Name: ORTIZ ENTERPRISES, INC.
Contractor Address: 6 Cushing, Suite 200, Irvine, CA 92618
Resident Engineer: Darcy Davis Structure Rep.: Leonard Romero
DIME Sample ID: 2016-11-09-14
TL Number from the TL Form: 1109
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 11/09/2016
Date that the sample was received by the laboratory/organization performing the testing: 11/14/2016
The quantity of what the sample constitutes: 3
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 953-1109
Structure unique identifier: Unknown
Structure name: HOFF WASH BRIDGE
The fabricator/manufacturer/facility name: CEMEX
The concrete mix design number: 1592247
The truck number from where the sample was collected: 5829
The batch plant ticket number from where the sample was collected: 44313162
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: PLANT
A detailed description of where the material sample was collected: LOAD 6
Where the material sample would have been placed if not sampled: HOFF WASH BRIDGE ABUT 3 FOOTING
From Lot No.: Unknown
Bag Lot No.: Unknown
DIME Test ID: 2016-11-09-14-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 12/07/2016
Date Tested: 12/07/2016
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
3
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
5.99 in
|
Average diameter of cylinder 3
|
6.00 in
|
Cross sectional area of cylinder 1
|
28.27 in^2
|
Cross sectional area of cylinder 2
|
28.18 in^2
|
Cross sectional area of cylinder 3
|
28.27 in^2
|
Compressive strength (to nearest 10 psi)
|
5090 psi
|
Maximum load on cylinder 1
|
145340 lb
|
Maximum load on cylinder 2
|
142130 lb
|
Maximum load on cylinder 3
|
143350 lb
|
Compressive strength of cylinder 1
|
5141.1 psi
|
Type of fracture pattern of cylinder 1
|
3
|
Compressive strength of cylinder 2
|
5043.6 psi
|
Compressive strength of cylinder 3
|
5070.7 psi
|
Type of fracture pattern of cylinder 2
|
2
|
Type of fracture pattern of cylinder 3
|
1
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
no data
|
Correction factor for cylinder 3
|
no data
|
Age of specimen
|
28 days
|
Age of specimen in hours
|
no data
|