Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2016-10-28-7
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Sample Organization Contact: (916) 227-7071
Type of Sample: Annual Source Testing
Type of Material: Cementitious
Sample Taken Date: 10/28/2016
Date that the sample was received by the laboratory/organization performing the testing: 10/28/2016
The quantity of what the sample constitutes: 1 Bucket
A brief description of the sample: Unknown
From where was the sample collected: Source
Laboratory sample identification: CM165660
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Spartan
DIME Test ID: 2016-10-28-7-1
Test Method: ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)
Verified Date: 03/22/2019
Date Tested: 11/29/2016
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
no
|
Compressive strength of 1st specimen (psi)
|
3410.25 psi
|
Compressive strength of 2nd specimen (psi)
|
4139.25 psi
|
Compressive strength of 3rd specimen (psi)
|
4122.75 psi
|
Average Compressive strength (to nearest 10 psi)
|
3890 psi
|
DIME Test ID: 2016-10-28-7-2
Test Method: ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)
Verified Date: 03/22/2019
Date Tested: 11/29/2016
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
yes
|
Compressive strength of 1st specimen (psi)
|
5117 psi
|
Compressive strength of 2nd specimen (psi)
|
5918.25 psi
|
Compressive strength of 3rd specimen (psi)
|
4986.5 psi
|
Average Compressive strength (to nearest 10 psi)
|
5340 psi
|
Average Compressive strength (to nearest 10 psi) control group
|
4770 psi
|
Strength Activity Index of Portland Cement per ASTM C311
|
112
|
DIME Test ID: 2016-10-28-7-3
Test Method: ASTM C430-8: Standard Test Method for Fineness of Hydraulic Cement by the 45-μm (No. 325) Sieve
Verified Date: 03/22/2019
Date Tested: 11/03/2016
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Correction Factor (CF)
|
0.15
|
Corrected Residue (Rc)
|
6.06
|