Sample Record for 2016-10-21-7
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 210734 DEA: 043G4574 EFIS: 0412000057
QA Service Level: 1
DIST-CO-RTE-PM: 04-CC,MRN,SF-580,580,80-580PM6.1/7.8,0.0/2.6,80PM5.7/7.7
Work Description: REPLACE JOINT SEALS, CONSTRUCT APPROACH SLAB, REPAIR DECK DRAINS
Location Description: IN CONTRA COSTA, MARIN, AND SAN FRANCISCO COUNTIES ON THE SANFRANCISCO-OAKLAND BAY BRIDGE ANDRICHMOND -SAN RAFAEL BRIDGE
Contractor Name: MYERS AND SONS CONSTRUCTION, LP
Contractor Address: 4600 NORTHGATE BLVD,SUITE 100, SACRAMENTO CA 9583
Resident Engineer: Ranjeet singh Structure Rep.: Pervez Randhawa
Sample Information
DIME Sample ID: 2016-10-21-7
TL Number from the TL Form: NA
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 10/21/2016
Date that the sample was received by the laboratory/organization performing the testing: 10/31/2016
The quantity of what the sample constitutes: 1
A brief description of the sample: Plain Bearing Pad
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: D S Brown
Material Information
Mfg. Lot Number(s): C1610-6072-09
Material/Compound/Elastomer ID: NA
Samples Representing: 81
Description (size): .5" x 8" x 12"
Comments: Unknown
Description (Number of Shims): 0
Type of Bearing Pad: Plain
Description (Thickness of Shims): NA
Manufacturer(s): D S Brown
Batch Number: NA
Test Results
Test 1 of 4
DIME Test ID: 2016-10-21-7-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 11/02/2016
Date Tested: 11/01/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 f
|
Humidity
|
50 %
|
Reading #1
|
58
|
Reading #2
|
56
|
Reading #3
|
58
|
Reading #4
|
57
|
Reading #5
|
58
|
Mean
|
57.4
|
Test 2 of 4
DIME Test ID: 2016-10-21-7-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 11/02/2016
Date Tested: 11/01/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
Unit of the Ultimate Tensile Values
|
lbf per sqr in
|
UTM
|
2KIP
|
Humidity
|
50 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.075 in
|
Sample 1 Thickness all Within 0.003 inch?
|
Yes
|
Sample 1 Ultimate Tensile
|
2766 lbf/in^2
|
Sample 1 Elongation (350% Min)
|
Pass
|
Sample 2 Median Thickness
|
0.076 in
|
Sample 2 Thickness all Within 0.003 inch?
|
Yes
|
Sample 2 Ultimate Tensile
|
2789.5 lbf/in^2
|
Sample 2 Elongation (350% Min)
|
Pass
|
Sample 3 Median Thickness
|
0.074 in
|
Sample 3 Thickness all Within 0.003 inch?
|
Yes
|
Sample 3 Ultimate Tensile
|
2702.7 lbf/in^2
|
Sample 3 Elongation (350% Min)
|
Pass
|
Median of the Ultimate Tensile Values
|
2766 lbf/in^2
|
Test 3 of 4
DIME Test ID: 2016-10-21-7-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 11/02/2016
Date Tested: 11/01/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
UTM
|
no data
|
Humidity
|
50 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.075 in
|
Sample 1 Tear Strength
|
280 lbf / in
|
Sample 2 Median Thickness
|
0.072 in
|
Sample 2 Tear Strength
|
305.6 lbf / in
|
Sample 3 Median Thickness
|
0.075 in
|
Sample 3 Tear Strength
|
266.7 lbf / in
|
Median of the Tear Strength Values
|
280 lb/in
|
Test 4 of 4
DIME Test ID: 2016-10-21-7-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 11/02/2016
Date Tested: 11/02/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: