Print Report | Back to Sample Detail

Sample Record for 2024-05-23-79

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994147 DEA: 120R4104 EFIS: 1218000090 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-1-17.4/21.5
Work Description: COLD PLANE AC AND PLACE RHMA-G.
Location Description: ORANGE COUNTY IN NEWPORT BEACH FROM JAMBOREE ROAD TO SANTA ANA RIVER BRIDGE
Contractor Name: R.J. NOBLE COMPANY
Contractor Address: 15505 E. Lincoln Ave, Orange, CA 92865
Resident Engineer: Omid Mazdiyasni Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-05-23-79
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 05/23/2024
Date that the sample was received by the laboratory/organization performing the testing: 06/07/2024
The quantity of what the sample constitutes: 1can
A brief description of the sample: Asphalt Rubber Binder
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: R J Noble -Orange

Material Information

Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2024-05-23-79-1
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 06/12/2024
Date Tested: 06/11/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 57 C
Softening Point Sample 2 57 C
Bath Liquid freshly boiled distilled water
Minutes Reaction no data

Test 2 of 3

DIME Test ID: 2024-05-23-79-2
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 06/12/2024
Date Tested: 06/12/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Determination Worked Penetration
Worked Penetration 50 0.1 mm

Test 3 of 3

DIME Test ID: 2024-05-23-79-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 06/12/2024
Date Tested: 06/12/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Final Dial reading (F1) 70 mm
Ball Penetration (P1) 5 mm
Final Dial reading (F2) 80 mm
Ball Penetration (P2) 5 mm
Final Dial reading (F3) 75 mm
Ball Penetration (P3) 5 mm
Resilience 1 35 %
Resilience 2 25 %
Resilience 3 30 %
Average Resilience 30 %
Minutes Reaction no data