Project ID: 993431 DEA: 080R9804 EFIS: 0812000225
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-40-5719
Work Description: BUILDING WORK AND MINOR CONCRETE.
Location Description: SAN BERNARDINO COUNTY IN NEEDLES AT THE NEEDLES MAINTENANCE STATION AT 800 SAN CLEMENTE STREET
Contractor Name: KANAAN CONSTRUCTION INC.
Contractor Address: Unknown
Resident Engineer: Anthony Doan Structure Rep.: Monty Navarro
DIME Sample ID: 2024-06-06-62
TL Number from the TL Form: 1068-66
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 06/06/2024
Date that the sample was received by the laboratory/organization performing the testing: 06/07/2024
The quantity of what the sample constitutes: 6
A brief description of the sample: Concrete Cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 1068-66
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Hi Grade Materials Littlerock
The concrete mix design number: CT675F25
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 8001136
Concrete batch plant: HI GRADE
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: FUEL TANK SLAB
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2024-06-06-62-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C1231 - Unbonded Elastomeric Pad Cap Cured in accordance with ASTM C511
Verified Date: 07/17/2024
Date Tested: 06/20/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Cross sectional area of cylinder 1
|
28.27 in^2
|
Cross sectional area of cylinder 2
|
28.27 in^2
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
Compressive strength (to nearest 10 psi)
|
3410 psi
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
6.00 in
|
Compressive strength of cylinder 1
|
3456.1 psi
|
Compressive strength of cylinder 2
|
3366.6 psi
|
Maximum load on cylinder 1
|
97705 lb
|
Maximum load on cylinder 2
|
95175 lb
|
Type of fracture pattern of cylinder 1
|
2
|
Type of fracture pattern of cylinder 2
|
2
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
14 days
|
DIME Test ID: 2024-06-06-62-2
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617 - Sulfur Mortar Cap Cured in accordance with ASTM C511
Verified Date: 07/05/2024
Date Tested: 07/04/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Cross sectional area of cylinder 1
|
28.37 in^2
|
Cross sectional area of cylinder 2
|
28.27 in^2
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Compressive strength (to nearest 10 psi)
|
3900 psi
|
Average diameter of cylinder 1
|
6.01 in
|
Average diameter of cylinder 2
|
6.00 in
|
Compressive strength of cylinder 1
|
3933.0 psi
|
Compressive strength of cylinder 2
|
3859.6 psi
|
Maximum load on cylinder 1
|
111580 lb
|
Maximum load on cylinder 2
|
109110 lb
|
Type of fracture pattern of cylinder 1
|
3
|
Type of fracture pattern of cylinder 2
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
28 days
|