Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 210735 DEA: 071193U4 EFIS: 0713000007
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-10-37.2/42.4
Work Description: CONSTRUCT HOV LANES, WIDEN BRIDGES, AND REALIGN RAMPS.
Location Description: IN LA COUNTY FROM CITRUS STREET IN WEST COVINA TO ROUTE 57 IN POMONA
Contractor Name: Guy F. Atkinson
Contractor Address: 18201 Von Karman Ave, Suite #800, IRVINE CA 92612
Resident Engineer: Rodolfo Cao Structure Rep.: David Win
DIME Sample ID: 2016-10-19-2
TL Number from the TL Form: NA
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM6 - Ductile Iron Cast Samples
Sample Taken Date: 10/19/2016
Date that the sample was received by the laboratory/organization performing the testing: 10/25/2016
The quantity of what the sample constitutes: 3
A brief description of the sample: Coupon Casting
From where was the sample collected: Distributor
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: BCI DSI
Heat Number (s): 09066, 09156, 09196
Part Number (s): 68 27 246
Material Specification: A536
Grades: 65-45-12
Metal Foundry Manufacturer (Mill): BCI
Prestressing Manufacturer: DSI
DIME Test ID: 2016-10-19-2-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 10/26/2016
Date Tested: 10/26/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
3
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | | 09066 | 0.493 | 0.1909 | 46532 | 74960 | 16.7 | Fred | | 09156 | 0.494 | 0.1917 | 48541 | 80400 | 14.8 | Fred | | 09196 | 0.494 | 0.1917 | 44751 | 70160 | 18.6 | Fred |
| |
UTM
|
67KIP
|
Temperature
|
72 F
|