Sample Record for 2024-04-02-57
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 994425 DEA: 040K5204 EFIS: 0416000098
QA Service Level: 1
DIST-CO-RTE-PM: 04-SON-12-11.0/T17.4
Work Description: Overlay with RHMA, replace guardrails, approach slabs and signs.
Location Description: Construction on State Highway in Sonoma County from Llano Road to Farmers Lane.
Contractor Name: FBD VANGUARD CONSTRUCTION, INC. (TOM SWISHER)
Contractor Address: 550 Greenville Road, Livermore, CA 94550
Resident Engineer: Cody Van Beek Structure Rep.: Anthony Tierra
Sample Information
DIME Sample ID: 2024-04-02-57
TL Number from the TL Form: Unknown
Sample Submitted By Organization: G3 Quality, Incorporated - Cerritos
Sample Organization Contact: (562) 321-9840
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 04/02/2024
Date that the sample was received by the laboratory/organization performing the testing: 04/03/2024
The quantity of what the sample constitutes: 6
A brief description of the sample: 6X12 Concrete Cylinders
From where was the sample collected: Job Site
Laboratory sample identification: HE4X4BM, Set 2
Structure unique identifier: 00-0000
Structure name:
The fabricator/manufacturer/facility name: Vanguard Construction
Material Information
The concrete mix design number: HE4X4BM
The truck number from where the sample was collected: Load 12
The batch plant ticket number from where the sample was collected: 0
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Set 2
A detailed description of where the material sample was collected: E/B RTE 12 to N/B RTE 101 Connector, Departure Slab
Where the material sample would have been placed if not sampled: Unknown
From Lot No.: 1
Bag Lot No.: 1
Test Results
Test 1 of 6
DIME Test ID: 2024-04-02-57-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 06/05/2024
Date Tested: 04/03/2024
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Average diameter of cylinder 1
|
6.01 in
|
Average diameter of cylinder 2
|
6.01 in
|
Cross sectional area of cylinder 1
|
28.37 in^2
|
Cross sectional area of cylinder 2
|
28.37 in^2
|
Compressive strength (to nearest 10 psi)
|
1930 psi
|
Maximum load on cylinder 1
|
54560 lb
|
Maximum load on cylinder 2
|
54970 lb
|
Type of fracture pattern of cylinder 1
|
5
|
Type of fracture pattern of cylinder 2
|
5
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
no data0 days
|
Age of specimen in hours
|
4 hours
|
Test 2 of 6
DIME Test ID: 2024-04-02-57-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 06/05/2024
Date Tested: 05/01/2024
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
6.00 in
|
Cross sectional area of cylinder 1
|
28.27 in^2
|
Cross sectional area of cylinder 2
|
28.27 in^2
|
Compressive strength (to nearest 10 psi)
|
8160 psi
|
Maximum load on cylinder 1
|
229620 lb
|
Maximum load on cylinder 2
|
231690 lb
|
Type of fracture pattern of cylinder 1
|
3
|
Type of fracture pattern of cylinder 2
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
28 days
|
Age of specimen in hours
|
no data0 hours
|
Test 3 of 6
DIME Test ID: 2024-04-02-57-3
Test Method: CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement Concrete
Verified Date: 06/05/2024
Date Tested: 04/02/2024
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Test 4 of 6
DIME Test ID: 2024-04-02-57-4
Test Method: CTM 518-June 2010: Method of Test for Unit Weight of Fresh Concrete
Verified Date: 06/05/2024
Date Tested: 04/02/2024
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit weight of the concrete
|
153.5 lb/ft^3
|
Cement content
|
no data0 lb/yd^3
|
Test 5 of 6
DIME Test ID: 2024-04-02-57-5
Test Method: CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 06/05/2024
Date Tested: 04/02/2024
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Test 6 of 6
DIME Test ID: 2024-04-02-57-6
Test Method: CTM 533-June 2010: Method of Test for Ball Penetration in Fresh Portland Cement Concrete
Verified Date: 06/05/2024
Date Tested: 04/02/2024
Submitted By Organization: G3 Quality, Incorporated - Cerritos
Organization Address: 13850 Cerritos Corporate Drive, Unit E,
Organization City: Cerritos
Organization State: CA
Organization Zipcode: 90703
Organization Email: hwalker@g3quality.com
Organization Phone: 562-321-9853
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Ball penetration in freshly mixed concrete (average)
|
2.5 inch
|