Print Report | Back to Sample Detail

Sample Record for 2016-10-12-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 211393 DEA: 081F1104 EFIS: 0814000160 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-38-38.6-L5759
Work Description: CONSTRUCT A SAND HOUSE AND CHAIN LINK FENCE AT ONYX SUMMIT
Location Description: SAN BERNARDINO COUNTY AT ONYX SUMMIT 0.7 MILES SOUTH OF PIPES ROAD
Contractor Name: BRM
Contractor Address: Unknown
Resident Engineer: Al-Hakem Alina Structure Rep.: Al-Hakem Alina

Sample Information

DIME Sample ID: 2016-10-12-3
TL Number from the TL Form: 001
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 10/12/2016
Date that the sample was received by the laboratory/organization performing the testing: 10/13/2016
The quantity of what the sample constitutes: 8
A brief description of the sample: 6X12
From where was the sample collected: Job Site
Laboratory sample identification: 949-01
Structure unique identifier: ONYX SUMMIT SAND HOUSE
Structure name: FOUNDATION
The fabricator/manufacturer/facility name: ROBERSTSONS

Material Information

The concrete mix design number: RRM09013
The truck number from where the sample was collected: 1728
The batch plant ticket number from where the sample was collected: 2318896
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: TAIL
Where the material sample would have been placed if not sampled: Unknown
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Results

Test 1 of 4

DIME Test ID: 2016-10-12-3-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
This test has been superseded on 10/26/2016.
Reason: retested

Test 2 of 4

DIME Test ID: 2016-10-12-3-4
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 11/09/2016
Date Tested: 11/09/2016
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 5.98 in
Average diameter of cylinder 2 5.99 in
Cross sectional area of cylinder 1 28.09 in^2
Cross sectional area of cylinder 2 28.18 in^2
Compressive strength (to nearest 10 psi) 5670 psi
Maximum load on cylinder 1 159990 lb
Maximum load on cylinder 2 159100 lb
Compressive strength of cylinder 1 5695.6 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 5645.8 psi
Type of fracture pattern of cylinder 2 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 no data
Age of specimen 28 days
Age of specimen in hours no data

Test 3 of 4

DIME Test ID: 2016-10-12-3-5
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 10/26/2016
Date Tested: 10/26/2016
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 5.98 in
Average diameter of cylinder 2 5.98 in
Cross sectional area of cylinder 1 28.09 in^2
Cross sectional area of cylinder 2 28.09 in^2
Compressive strength (to nearest 10 psi) 4500 psi
Maximum load on cylinder 1 124760 lb
Maximum load on cylinder 2 128030 lb
Compressive strength of cylinder 1 4441.4 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 4557.8 psi
Type of fracture pattern of cylinder 2 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 no data
Age of specimen 14 days
Age of specimen in hours no data

Test 4 of 4

DIME Test ID: 2016-10-12-3-6
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 10/26/2016
Date Tested: 10/19/2016
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 5.98 in
Average diameter of cylinder 2 5.99 in
Cross sectional area of cylinder 1 28.09 in^2
Cross sectional area of cylinder 2 28.18 in^2
Compressive strength (to nearest 10 psi) 3710 psi
Maximum load on cylinder 1 105540 lb
Maximum load on cylinder 2 103110 lb
Compressive strength of cylinder 1 3757.2 psi
Type of fracture pattern of cylinder 1 1
Compressive strength of cylinder 2 3659.0 psi
Type of fracture pattern of cylinder 2 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 no data
Age of specimen 7 days
Age of specimen in hours no data