Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 210097 DEA: 100L9704 EFIS: 1012000053
QA Service Level: 1
DIST-CO-RTE-PM: 10-TUO-120-R19.5/R20.0
Work Description: REPLACE DECK AND RETROFIT BRIDGE.
Location Description: IN TUOLUMNE COUNTY ON STATE ROUTE 120 FROM 7.6 MILES EAST OF YOSEMITEJUNCTION TO 4.8 MILES WEST OF THE TOWN OF MOCCASIN AT TUOLUMNE RIVER/DON PEDRO RESERVOIR (JAMES E.
Contractor Name: Golden State Bridge
Contractor Address: 3701 Mallard Drive, Benicia, CA 94510
Resident Engineer: Corey Casey Structure Rep.: Ehab Wahed
DIME Sample ID: 2016-10-12-1
TL Number from the TL Form: NA
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM6 - Ductile Iron Cast Samples
Sample Taken Date: 10/12/2016
Date that the sample was received by the laboratory/organization performing the testing: 10/13/2016
The quantity of what the sample constitutes: 2
A brief description of the sample: Coupon Casting
From where was the sample collected: Distributor
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: SDI Urick
Heat Number (s): 27K4 10L4
Part Number (s): SDI14 6A
Material Specification: A536
Grades: 80-55-06
Metal Foundry Manufacturer (Mill): Urick
Prestressing Manufacturer: SDI
DIME Test ID: 2016-10-12-1-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 10/13/2016
Date Tested: 10/13/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
2
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | | DI12 | 0.498 | 0.1948 | 61386 | 108950 | 8.3 | Fred | | DI12 | 0.498 | 0.1948 | 60415 | 106840 | 9.4 | Fred |
| |
UTM
|
67KIP
|
Temperature
|
72 F
|