Print Report | Back to Sample Detail

Sample Record for 2024-05-29-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214698 DEA: 120N8904 EFIS: 1214000130 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-133-8.3/M9.3
Work Description: CONSTRUCT AUXILIARY LANE.
Location Description: ORANGE COUNTY IN IRVINE FROM ROUTE 133/405 SEPARATION TO IRVINE CENTER DRIVE OVERCROSSING
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 3200 Park Center Drive, Suite #200, Costa Mesa, CA 92626
Resident Engineer: Arezo Ghiam Structure Rep.: Melissa Quintana

Sample Information

DIME Sample ID: 2024-05-29-1
TL Number from the TL Form: L140-041-24
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM7 - Epoxy Coated Rebar
Sample Taken Date: 05/29/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/31/2024
The quantity of what the sample constitutes: 130
A brief description of the sample: Epoxy Anchor Dowels
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Western Coatings

Material Information

Rebar Heat Number(s): 1201056569
Rebar Epoxy Batch Number(s): CH3553NL
Rebar Coating Specification: ASTM A775
Rebar Size (#): 6
Rebar Coating Color: Green
Rebar Manufacturer: Nucor
Rebar Coater: Western Coating Ogden UT
Rebar Powder Manufacturer: Sherwin Williams
Release Number: 211-E1, 212-E1, 212-ET,216-E1
Quality Assurance Code:

Test Results

Test 1 of 2

DIME Test ID: 2024-05-29-1-1
Test Method: ASTM A775-19: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Verified Date: 06/11/2024
Date Tested: 06/06/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
First Bar Mean 10.13
Second Bar Mean 10.4
Lower spec. limit LSL 7
Upper spec. limit USL 16
Bar # for First Bar 1
Bar # for Second Bar 2
Total mean value 10.26
Total number of values less than LSL no data
Total number of values greater than USL no data

Test 2 of 2

DIME Test ID: 2024-05-29-1-2
Test Method: ASTM A775-19: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)
Verified Date: 06/11/2024
Date Tested: 06/06/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Total Number of Holiday no data0
Total Length 5
Holidays Per Linear Foot of Bar no data0 holiday per ft
Holiday Test Pass/Fail Pass
Bend Test Pass/Fail Pass