Print Report | Back to Sample Detail

Sample Record for 2016-09-26-6

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 211068 DEA: 080N5504 EFIS: 0800020102 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-40-R105.2/R106.5
Work Description: REPLACE THE LEFT WATSON WASH BRIDGE N0. 0805L
Location Description:
Contractor Name: MCM Construction
Contractor Address: PO Box 620, North Highlands, Ca 95660
Resident Engineer: Darcy Davis Structure Rep.: Leonard Romero

Sample Information

DIME Sample ID: 2016-09-26-6
TL Number from the TL Form: SRL 1
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 09/26/2016
Date that the sample was received by the laboratory/organization performing the testing: 10/03/2016
The quantity of what the sample constitutes: 2
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Other
Laboratory sample identification: 947-SRL1
Structure unique identifier: Unknown
Structure name: WATSON WASH BRIDGE
The fabricator/manufacturer/facility name: CEMEX

Material Information

The concrete mix design number: 1592266
The truck number from where the sample was collected: 35775
The batch plant ticket number from where the sample was collected: 43823706
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: LOAD 1
Where the material sample would have been placed if not sampled: TRIAL BATCH
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Results

Test 1 of 2

DIME Test ID: 2016-09-26-6-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
This test has been superseded on 10/24/2016.
Reason: corrected

Test 2 of 2

DIME Test ID: 2016-09-26-6-3
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 10/24/2016
Date Tested: 10/24/2016
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 6
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 5.99 in
Average diameter of cylinder 2 5.99 in
Average diameter of cylinder 3 5.99 in
Average diameter of cylinder 4 5.98 in
Average diameter of cylinder 5 5.99 in
Average diameter of cylinder 6 5.99 in
Cross sectional area of cylinder 1 28.18 in^2
Cross sectional area of cylinder 2 28.18 in^2
Cross sectional area of cylinder 3 28.18 in^2
Cross sectional area of cylinder 4 28.09 in^2
Cross sectional area of cylinder 5 28.18 in^2
Cross sectional area of cylinder 6 28.18 in^2
Compressive strength (to nearest 10 psi) 5720 psi
Maximum load on cylinder 1 161510 lb
Maximum load on cylinder 2 164830 lb
Maximum load on cylinder 3 155610 lb
Maximum load on cylinder 4 161490 lb
Maximum load on cylinder 5 163120 lb
Maximum load on cylinder 6 160110 lb
Compressive strength of cylinder 1 5731.4 psi
Type of fracture pattern of cylinder 1 1
Compressive strength of cylinder 2 5849.2 psi
Compressive strength of cylinder 3 5522 psi
Compressive strength of cylinder 4 5749 psi
Compressive strength of cylinder 5 5788.5 psi
Compressive strength of cylinder 6 5681.7 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 3
Type of fracture pattern of cylinder 4 1
Type of fracture pattern of cylinder 5 2
Type of fracture pattern of cylinder 6 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 no data
Correction factor for cylinder 3 no data
Correction factor for cylinder 4 no data
Correction factor for cylinder 5 no data
Correction factor for cylinder 6 no data
Age of specimen 28 days
Age of specimen in hours no data