Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214579 DEA: 010B0904 EFIS: 0100020444
QA Service Level: 1
DIST-CO-RTE-PM: 01-DN-101-8.2/8.7
Work Description: Panther Creek & Hunter Creek Bridges
Location Description: DEL NORTE COUNTY NEAR KLAMATH AT PANTHER CREEK BRIDGE AND AT HUNTER CREEK BRIDGE
Contractor Name: Golden State Bridge, Inc
Contractor Address: 3701 Mallard Dr., Benicia, CA 94510
Resident Engineer: Ryan Dunne Structure Rep.: Brian Cinkutis
DIME Sample ID: 2024-05-13-62
TL Number from the TL Form: 637131
Sample Submitted By Organization: CT D01 - District 1 Materials Laboratory
Sample Organization Contact: (707) 496-0974
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/13/2024
Date that the sample was received by the laboratory/organization performing the testing: 05/14/2024
The quantity of what the sample constitutes: 1 day of paving
A brief description of the sample: 1/2" HMA-A PG 64-16
From where was the sample collected: Job Site
Laboratory sample identification: 24-069
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Mercer Fraser Boyd Road
DIME Test ID: 2024-05-13-62-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 05/16/2024
Date Tested: 05/11/2024
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1726 Albee Street,
Organization City: Eureka
Organization State: CA
Organization Zipcode: 95501
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Celsius
|
Test procedure used?
|
Method A
|
Mass of HMA Sample prior to ignition
|
1720.8 g
|
Corrected Asphalt Binder Content
|
5.23 %
|
Mass Loss
|
104.5 g
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.84 %
|
Moisture Content
|
no data0 %
|
Temperature Compensation Factor
|
no data0 %
|
Test Temperature
|
482 C
|