Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994443 DEA: 053307C4 EFIS: 0514000028
QA Service Level: 1
DIST-CO-RTE-PM: 05-SLO-41,46-44.5/45.3,54.0/57.8
Work Description: Wye Segment - Route 41/46 Separation
Location Description:
Contractor Name: Atkinson Construction
Contractor Address: 18201 Von Karman - Suite 800, Irvine, CA 92612
Resident Engineer: Brian Harrington Structure Rep.: Dave Lewis
DIME Sample ID: 2024-04-15-78
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - Whitley Gardens Field Laboratory
Sample Organization Contact: 805-540-9933
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 04/15/2024
Date that the sample was received by the laboratory/organization performing the testing: 04/16/2024
The quantity of what the sample constitutes: Sep. Brdge Abut 3 Shear Key - 3T40H001
A brief description of the sample: 4x8 Concrete Cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name: Sep. Bridge Abut 3 Shear Key
The fabricator/manufacturer/facility name: Holliday Rock - Paso Robles
The concrete mix design number: 3T40H001
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: NA
Concrete batch plant: Holliday Rock Company
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Mix Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2024-04-15-78-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 05/13/2024
Date Tested: 05/13/2024
Submitted By Organization: CT D05 - Whitley Gardens Field Laboratory
Organization Address: 102 South Whitley Gardens Drive,
Organization City: Paso Robles
Organization State: CA
Organization Zipcode: 93346
Organization Email: kyle.engen@dot.ca.gov
Organization Phone: (805) 540-9933
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
3
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Average diameter of cylinder 1
|
3.99 in
|
Average diameter of cylinder 2
|
3.99 in
|
Average diameter of cylinder 3
|
3.99 in
|
Cross sectional area of cylinder 1
|
12.5 in^2
|
Cross sectional area of cylinder 2
|
12.5 in^2
|
Cross sectional area of cylinder 3
|
12.5 in^2
|
Compressive strength (to nearest 10 psi)
|
7620 psi
|
Maximum load on cylinder 1
|
90389 lb
|
Maximum load on cylinder 2
|
100290 lb
|
Maximum load on cylinder 3
|
95118 lb
|
Compressive strength of cylinder 1
|
7231.1 psi
|
Type of fracture pattern of cylinder 1
|
2
|
Compressive strength of cylinder 2
|
8023.2 psi
|
Compressive strength of cylinder 3
|
7609.4 psi
|
Type of fracture pattern of cylinder 2
|
4
|
Type of fracture pattern of cylinder 3
|
4
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Correction factor for cylinder 3
|
1
|
Age of specimen
|
28 days
|
Age of specimen in hours
|
0 hours
|