STATE OF CALIFORNIA - CALIFORNIA STATE TRANSPORTATION AGENCY

Gavin Newsom, Governor


DEPARTMENT OF TRANSPORTATION

DIVISION OF ENGINEERING SERVICES

MATERIALS ENGINEERING AND TESTING SERVICES

Concrete Materials Testing Branch

5900 Folsom Blvd.

Sacramento, CA 95819

916-227-7205

image

Contract # 041A2904 Cty SON Rte 12 PM 9.6

Vendor #


REPORT OF LABORATORY TESTING

Resident Engineer:

Syd Valeh

Date Reported:

09/26/2016

Address:

TL Number:

256231

City:

Project Name: REPLACE BRIDGE AND WIDEN APPROACHES.

Prime Contractor: GHILOTTI CONSTRUCTION COMPANY

Sample Taken Date:

09/20/2016

Mix Design:

b7181sra

Contractor: Unknown

Location : SONOMA COUNTY NEAR THE CITY OF SEBASTOPOL AT LAGUNA DE SANTA ROSA BRIDGE

Structure unique identifier: Unknown

Structure name: Unknown

Location of Pour: Unknown


The following testing has been tested in accordance with:

ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens

Capped in accordance with ASTM C617/CTM521

Cured in accordance with ASTM C511

SpecimenAverage diameter of cylinder (in)Cross sectional area of cylinder (in^2)Maximum load on cylinder (lb)Compressive strength of cylinder (psi)Type of fracture pattern of cylinder
15.9727.99769092747.71
25.9727.99766332737.91

DIME Test ID: 2016-09-20-7-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 2740
Age of specimen: 6 days
Certified By: Mike Mullins



Summary of Items Observed and Conversations:

Comments: This report is for the purpose of reporting test results.
Should you require recommendations concerning repairs or remedial efforts please contact the METS representative,
who represents the Materials Engineering and Testing Services for your project.

*Subject to final inspection by the Resident Engineer.




TL- Report of Laboratory Testing