Sample Record for 2016-09-07-3
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 209732 DEA: 072881U4 EFIS: 0714000085
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-210-R16.1/R25.8
Work Description: CONSTRUCT CONCRETE PAVEMENT, PRECAST CONCRETE PANELS, AND SLABS.
Location Description: LOS ANGELES COUNTY IN LA CANADA FLINTRIDGE, GLENDALE AND PASADENA FROM DUNSMORE AVENUE UNDERCROSSING TO NORTH LOS ROBLES AVENUE OVERCROSSING
Contractor Name: FLATIRON WEST, INC.
Contractor Address: 1770 LA COSTA MEADOWS DRIVE, SAN MARCOS, CA 92078
Resident Engineer: Sushil Chaudhari Structure Rep.: Mark Amorsolo
Sample Information
DIME Sample ID: 2016-09-07-3
TL Number from the TL Form: 927-16F
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 09/07/2016
Date that the sample was received by the laboratory/organization performing the testing: 09/09/2016
The quantity of what the sample constitutes: 2
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 927-16F
Structure unique identifier: Unknown
Structure name: UC Structure
The fabricator/manufacturer/facility name: Jobsite
Material Information
The concrete mix design number: UV-288
The truck number from where the sample was collected: Unknown
The batch plant ticket number from where the sample was collected: 54474
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: jobsite
A detailed description of where the material sample was collected: Concrete from wheelbarrow
Where the material sample would have been placed if not sampled: Unknown
From Lot No.: Unknown
Bag Lot No.: Unknown
Test Results
Test 1 of 1
DIME Test ID: 2016-09-07-3-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Verified Date: 09/21/2016
Date Tested: 09/21/2016
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Cross sectional area of cylinder 1
|
28.56 in^2
|
Cross sectional area of cylinder 2
|
28.56 in^2
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Compressive strength (to nearest 10 psi)
|
6590 psi
|
Average diameter of cylinder 1
|
6.03 in
|
Average diameter of cylinder 2
|
6.03 in
|
Compressive strength of cylinder 1
|
6553.6 psi
|
Compressive strength of cylinder 2
|
6617.6 psi
|
Maximum load on cylinder 1
|
187170 lb
|
Maximum load on cylinder 2
|
189000 lb
|
Type of fracture pattern of cylinder 1
|
2
|
Type of fracture pattern of cylinder 2
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
no data
|
Age of specimen
|
14 days
|