Print Report | Back to Sample Detail

Sample Record for 2016-07-20-13

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 8196 DEA: 59912684 QA Service Level: 1
DIST-CO-RTE-PM: 59---
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2016-07-20-13
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM6 - Ductile Iron Cast Samples
Sample Taken Date: 07/20/2016
Date that the sample was received by the laboratory/organization performing the testing: 09/02/2016
The quantity of what the sample constitutes: 2
A brief description of the sample: A536 Ductile Iron
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Stressteel Farrar

Material Information

Heat Number (s): G206
Part Number (s): ACS 12 6 AH
Material Specification: A536
Grades: 80-55-06
Metal Foundry Manufacturer (Mill): Farrar
Prestressing Manufacturer: Stressteel

Test Results

Test 1 of 1

DIME Test ID: 2016-07-20-13-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 09/07/2016
Date Tested: 09/06/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 2
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
G2060.49850.1952652011122509.5Arnold
G2060.49830.1956487811264010Arnold
UTM 67KIP
Temperature 72 F