Project Information

Project ID: 994405 DEA: 080F5414 EFIS: 0800000137 COOP: 081743 QA Service Level: 2
DIST-CO-RTE-PM: 08-RIV--
Work Description: RIV 71/91 FLYOVER
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Mohsen Javaherneshan Structure Rep.: Anton Schmieder

Sample Information

DIME Sample ID: 2024-03-20-71
TL Number from the TL Form:
Sample Submitted By Organization: Surecast West
Sample Organization Contact: (951) 491-9506
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 03/20/2024
Date that the sample was received by the laboratory/organization performing the testing: 04/05/2024
The quantity of what the sample constitutes: 10.00 cy
A brief description of the sample: TYPE II / V
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CEMEX-REDLANDS

Material Information

The concrete mix design number: 1610974
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 31136251
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: CONCRETE SAMPLE FROM WHEELBARROW
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2024-03-20-71-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 04/19/2024
Date Tested: 04/05/2024
Submitted By Organization: Surecast West
Organization Address: 8203 Alabama Street,
Organization City: Redlands
Organization State: CA
Organization Zipcode: 92373
Organization Email: cody@surecastwest.com
Organization Phone: (951) 491-9506
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 4630 psi
Maximum load on cylinder 1 57950 lb
Maximum load on cylinder 2 57570 lb
Maximum load on cylinder 3 58950 lb
Type of fracture pattern of cylinder 1 1
Type of fracture pattern of cylinder 2 1
Type of fracture pattern of cylinder 3 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 16 days
Age of specimen in hours 0 hours