Sample Record for 2016-08-30-2
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 208679 DEA: 100S1104 EFIS: 1000000229 COOP: 10406
QA Service Level: 1
DIST-CO-RTE-PM: 10-SJ-4,5-Var
Work Description: SR-4 FREEWAY EXTENSION
Location Description: IN SAN JOAQUIN COUNTY
Contractor Name: BROSAMER & WALL, INC.
Contractor Address: 1777 Oakland Blvd., Suite 110, Walnut Creek, CA 94596
Resident Engineer: Harminder Deol Structure Rep.: Alex Lara
Sample Information
DIME Sample ID: 2016-08-30-2
TL Number from the TL Form: C739932
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 08/30/2016
Date that the sample was received by the laboratory/organization performing the testing: 08/31/2016
The quantity of what the sample constitutes: 8
A brief description of the sample: Flash Welded Rebar Hoops
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Harris Salinas
Material Information
Production or Authorization Testing: Production Testing
Service or Ultimate: Ultimate
Rebar Heat Number(s): 586353
Hoop Manufacturer Lot Number(s): H03 H04
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: 5
Diameter of Hoop: 2'-8"
Epoxy Coated: Yes
Epoxy Coating Color: NA
Rebar Manufacturer: Harris Salinas
Welding Company: Harris Rebar
Coating Standards: Uncoated
Weld Type: Flash Welded
Test Results
Test 1 of 6
DIME Test ID: 2016-08-30-2-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 08/31/2016
Date Tested: 08/31/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Broke; OK Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By | 1 | H03 | #5/16mm | 0.31 | 29330 | 94610 | Bar Broke | Brian |
| |
UTM
|
400KIP
|
Temperature
|
72 F
|
Test 2 of 6
DIME Test ID: 2016-08-30-2-2
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 08/31/2016
Date Tested: 08/31/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Broke; OK Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By | 2 | H03 | #5/16mm | 0.31 | 28450 | 91770 | Bar Broke | Brian |
| |
UTM
|
400KIP
|
Temperature
|
72 F
|
Test 3 of 6
DIME Test ID: 2016-08-30-2-3
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 08/31/2016
Date Tested: 08/31/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Broke; OK Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By | 3 | H03 | #5/16mm | 0.31 | 29360 | 94710 | Bar Broke | Brian |
| |
UTM
|
400KIP
|
Temperature
|
72 F
|
Test 4 of 6
DIME Test ID: 2016-08-30-2-4
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 08/31/2016
Date Tested: 08/31/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Broke; OK Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By | 1 | H04 | #5/16mm | 0.31 | 29540 | 95290 | Bar Broke | Brian |
| |
UTM
|
400KIP
|
Temperature
|
72 F
|
Test 5 of 6
DIME Test ID: 2016-08-30-2-5
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 08/31/2016
Date Tested: 08/31/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Broke; OK Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By | 2 | H04 | #5/16mm | 0.31 | 29590 | 95450 | Bar Broke | Brian |
| |
UTM
|
400KIP
|
Temperature
|
72 F
|
Test 6 of 6
DIME Test ID: 2016-08-30-2-6
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 08/31/2016
Date Tested: 08/31/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Broke; OK Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By | 3 | H04 | #5/16mm | 0.31 | 29950 | 96610 | Bar Broke | Brian |
| |
UTM
|
400KIP
|
Temperature
|
72 F
|