Print Report | Back to Sample Detail

Sample Record for 2024-04-11-41

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993529 DEA: 11430514 EFIS: 1119000008 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-15-R31.3/R37.1
Work Description: CRCP, FIBER OPTIC CABLE, AND HMA.
Location Description: SAN DIEGO COUNTY IN AND NEAR ESCONDIDO FROM 0.2 MILE SOUTH OF ROUTE 15/78 SEPARATION TO 0.5 MILE NORTH OF DEER SPRINGS ROAD OVERCROSSING
Contractor Name: Security Paving Company, Inc.
Contractor Address: 13170 Telfair Ave, Sylmar, CA 91342
Resident Engineer: Jason Alsheikh Structure Rep.: Tan Cao

Sample Information

DIME Sample ID: 2024-04-11-41
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 688-1570
Type of Sample: Quality Assurance
Type of Material: Aggregate
Sample Taken Date: 04/11/2024
Date that the sample was received by the laboratory/organization performing the testing: 04/12/2024
The quantity of what the sample constitutes: 3 Bags
A brief description of the sample: 3/4" HMA PSU
From where was the sample collected: Source
Laboratory sample identification: 6638-PSU
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marietta

Material Information

Source Identification (SMARA, name of Pit or Job Site): N/A
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test 1 of 10

DIME Test ID: 2024-04-11-41-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 04/22/2024
Date Tested: 04/18/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 93 %
Cumulative percent passing the 1/2 in. sieve 69 %
Cumulative percent passing the 3/8 in. sieve 52 %
Cumulative percent passing the #4 sieve 31 %
Cumulative percent passing the #8 sieve 20 %
Cumulative percent passing the #16 sieve 12 %
Cumulative percent passing the #30 sieve 7 %
Cumulative percent passing the #50 sieve 3 %
Cumulative percent passing the #100 sieve 1 %
Cumulative percent passing the #200 sieve 0.1 %

Test 2 of 10

DIME Test ID: 2024-04-11-41-2
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 04/22/2024
Date Tested: 04/18/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Method 1 - Combined Fracture Determination
Aggregate Size and Fracture Type Coarse 2 Faced
Percentage of questionable, coarse, 2 faced particles tested 0 %
Percentage of fractured, coarse, 2 faced particles tested 98 %

Test 3 of 10

DIME Test ID: 2024-04-11-41-3
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Verified Date: 04/22/2024
Date Tested: 04/18/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Method A
Determination By Number
Dimensional ratio used 5:1
Weighted percentage of particles (by number) that were flat 0 %
Weighted percentage of particles (by number) that were elongated 0 %
Weighted percentage of particles (by number) that were both flat and elongated 6 %
Weighted percentage of particles (by number) that were neither flat nor elongated 394 %

Test 4 of 10

DIME Test ID: 2024-04-11-41-4
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 04/22/2024
Date Tested: 04/18/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
Sand Equivalent 67

Test 5 of 10

DIME Test ID: 2024-04-11-41-5
Test Method: CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)
Verified Date: 04/22/2024
Date Tested: 04/18/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Plastic limit (PL) 1 %

Test 6 of 10

DIME Test ID: 2024-04-11-41-6
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 04/22/2024
Date Tested: 04/18/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Bulk specific gravity 2.514
Bulk specific gravity (SSD Basis) 2.577
Apparent specific gravity 2.684
Absorption 2.5 %

Test 7 of 10

DIME Test ID: 2024-04-11-41-7
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 04/22/2024
Date Tested: 04/18/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
Basis for relative density testing Bulk
Specific Gravity 2.618
Absorption 0.9 %

Test 8 of 10

DIME Test ID: 2024-04-11-41-8
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 04/22/2024
Date Tested: 04/18/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
Grading designation B
Mass of sample on No.12 sieve (after 500 revolutions) 4138 grams
Percent loss after 100 revolutions 7 %
Percent loss after 500 revolutions 17 %

Test 9 of 10

DIME Test ID: 2024-04-11-41-9
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Verified Date: 04/22/2024
Date Tested: 04/18/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What test method is performed? Method A
Bulk dry specific gravity 2.514
Average uncompacted voids 45.5 %

Test 10 of 10

DIME Test ID: 2024-04-11-41-10
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 04/22/2024
Date Tested: 04/18/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Is an aggregate correction factor used? No
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 100 %
Cumulative percent passing the 3/8 in. sieve 99 %
Cumulative percent passing the #4 sieve 82 %
Cumulative percent passing the #8 sieve 64 %
Cumulative percent passing the #16 sieve 49 %
Cumulative percent passing the #30 sieve 36 %
Cumulative percent passing the #50 sieve 24 %
Cumulative percent passing the #100 sieve 16 %
Cumulative percent passing the #200 sieve 10.6 %