Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 030L0804 Cty SAC Rte 51 PM 5.5/5.5 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Jony Tji |
Date Reported: |
05/08/2024 |
|
Address: |
TL Number: |
114913 |
||
City: |
||||
Project Name: Bridge Rail Replacement due to Vehicle Strike |
||||
Prime Contractor: RA NEMETZ |
||||
Sample Taken Date: |
04/10/2024 |
Mix Design: |
CT590133 |
|
Contractor: Unknown |
Location : Marconi Bridge |
|||
Structure unique identifier: |
||||
Structure name: |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.01 | 12.63 | 56257 | 4455.0 | 1 |
2 | 4.00 | 12.57 | 56987 | 4535.0 | 1 |
3 | 4.00 | 12.57 | 52964 | 4215 | 1 |
DIME Test ID: 2024-04-10-31-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 4400
Age of specimen: 28 days
Certified By: Spencer Adams
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing