Sample Record for 2024-04-10-2
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 993333 DEA: 04264724 EFIS: 0419000068
QA Service Level: 1
DIST-CO-RTE-PM: 04-MRN-101-R20.8/27.1
Work Description: CIP BRIDGES, CONSTRUCT ROADWAY, RETAINING WALLS AND MODIFY ELECTRICAL.
Location Description: MARIN COUNTY IN AND NEAR NOVATO FROM 0.1 MILE SOUTH OF FRANKLIN AVENUE OVERHEAD TO 0.5 MILE SOUTH OF SAN ANTONIO CREEK BRIDGE
Contractor Name: GHILOTTI CONSTRUCTION CO. INC. (RILEY GENAZZI & JOSH SERAFINO)
Contractor Address: 246 GHILOTTI AVE., SANTA ROSA, CA 95407
Resident Engineer: Fabio La Serna Structure Rep.: Jeremy Light
Sample Information
DIME Sample ID: 2024-04-10-2
TL Number from the TL Form:
Sample Submitted By Organization: CT SC - 3672 - Novato
Sample Organization Contact: (916) 621-8033
Type of Sample: Department Acceptance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 04/10/2024
Date that the sample was received by the laboratory/organization performing the testing: 04/10/2024
The quantity of what the sample constitutes: 1 Elastomeric Bearing Pad
A brief description of the sample: 4.6"x16"x16"
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier: 27-0090L
Structure name: Franklin Ave. OH Abut5
The fabricator/manufacturer/facility name: Scougal Rubber
Material Information
Mfg. Lot Number(s): 24502-1
Material/Compound/Elastomer ID: 55 Duro
Samples Representing: 4 samples
Description (size): 4.6"x16"x16"
Comments:
Description (Number of Shims): 8
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal Rubber
Batch Number: 1
Test Results
Test 1 of 4
DIME Test ID: 2024-04-10-2-1
Test Method: ASTM D2240-15r21: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 04/11/2024
Date Tested: 04/11/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature
|
72 f
|
Humidity
|
50 %
|
Reading #1
|
54
|
Reading #2
|
55
|
Reading #3
|
53
|
Reading #4
|
54
|
Reading #5
|
54
|
Mean
|
54
|
Test 2 of 4
DIME Test ID: 2024-04-10-2-2
Test Method: ASTM D412-16r21: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 04/11/2024
Date Tested: 04/11/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
Unit of the Ultimate Tensile Values
|
lbf per sqr in
|
UTM
|
2kip
|
Humidity
|
50.00 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.07
|
Sample 1 Thickness all Within 0.003 inch?
|
Yes
|
Sample 1 Ultimate Tensile
|
2390.26 lbf/in^2
|
Sample 1 Elongation (350% Min)
|
Pass
|
Sample 2 Median Thickness
|
0.071
|
Sample 2 Thickness all Within 0.003 inch?
|
Yes
|
Sample 2 Ultimate Tensile
|
2728.83 lbf/in^2
|
Sample 2 Elongation (350% Min)
|
Pass
|
Sample 3 Median Thickness
|
0.075
|
Sample 3 Thickness all Within 0.003 inch?
|
Yes
|
Sample 3 Ultimate Tensile
|
2334.13 lbf/in^2
|
Sample 3 Elongation (350% Min)
|
Pass
|
Median of the Ultimate Tensile Values
|
2390.3 lbf/in^2
|
Test 3 of 4
DIME Test ID: 2024-04-10-2-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 04/11/2024
Date Tested: 04/11/2024
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Test 4 of 4
DIME Test ID: 2024-04-10-2-5
Test Method: ASTM D624-00r20: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 04/11/2024
Date Tested: 04/11/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
UTM
|
2kip
|
Humidity
|
50.00 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.079
|
Sample 1 Tear Strength
|
206.1
|
Sample 2 Median Thickness
|
0.07
|
Sample 2 Tear Strength
|
201.1
|
Sample 3 Median Thickness
|
0.074
|
Sample 3 Tear Strength
|
189
|
Median of the Tear Strength Values
|
201.1 lb/in
|