Print Report | Back to Sample Detail

Sample Record for 2016-08-22-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 211047 DEA: 081C0914 EFIS: 0814000223 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-60-R12.2/22.1&26.5/30.4
Work Description: MILL AND OVERLAY MAINLINE PAVEMENT, SHOULDERS, RAMPS, INCLUDE DIGOUTS
Location Description: MILL AND OVERLAY MAINLINE PAVEMENT, SHOULDERS, RAMPS, INCLUDE DIGOUTS
Contractor Name: ALL AMERICAN ASPHALT
Contractor Address: 400 East 6th Street, Corona, CA 92879
Resident Engineer: Miguel Calixto Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2016-08-22-4
TL Number from the TL Form: 1
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 08/22/2016
Date that the sample was received by the laboratory/organization performing the testing: 08/26/2016
The quantity of what the sample constitutes: 4
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 944-1
Structure unique identifier: NOT PROVIDED
Structure name: RTE 60
The fabricator/manufacturer/facility name: CEMEX

Material Information

The concrete mix design number: 1419984
The truck number from where the sample was collected: 10037110
The batch plant ticket number from where the sample was collected: 42440034
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: PLANT
A detailed description of where the material sample was collected: NOT PROVIDED
Where the material sample would have been placed if not sampled: NOT PROVIDED
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Results

Test 1 of 1

DIME Test ID: 2016-08-22-4-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/29/2016
Date Tested: 08/29/2016
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 6.03 in
Average diameter of cylinder 2 6.03 in
Cross sectional area of cylinder 1 28.56 in^2
Cross sectional area of cylinder 2 28.56 in^2
Compressive strength (to nearest 10 psi) 900 psi
Maximum load on cylinder 1 25410 lb
Maximum load on cylinder 2 25760 lb
Compressive strength of cylinder 1 889.7 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 902.0 psi
Type of fracture pattern of cylinder 2 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 no data
Age of specimen 7 days
Age of specimen in hours no data