Print Report | Back to Sample Detail

Sample Record for 2024-04-02-11

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-04-02-11
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 04/02/2024
Date that the sample was received by the laboratory/organization performing the testing: 04/02/2024
The quantity of what the sample constitutes: 9
A brief description of the sample: 1 1/2-6 x 3 3/4" A325 HVY HX Bolt
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: QFC Industries

Material Information

Rocap Number(s):
Heat Number(s): 20903560
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: ASTM A325
Bolt Length(s):
Nut Specification: na
Washer Specification: na
Finish:
Diameter/Size:
Bolt Mfg. Lot Number: 116031
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Results

Test 1 of 3

DIME Test ID: 2024-04-02-11-1
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 04/08/2024
Date Tested: 04/08/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 116031
Finish Coating ASTM F2329 - Hot Dip
Product Markings FF A325
Size 1.5 in
Bolt Length 3.75 in
Gage Type Pass

Test 2 of 3

DIME Test ID: 2024-04-02-11-2
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/08/2024
Date Tested: 04/08/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 116031
Finish Coating ASTM F2329 - Hot Dip
Product Markings FF A325
Size 1.5 in
Bolt Length 3.75 in
Measurement Average 2.36 mils

Test 3 of 3

DIME Test ID: 2024-04-02-11-3
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 04/08/2024
Date Tested: 04/08/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 116031
Finish Coating ASTM F2329 - Hot Dip
Product Markings FF A325
Size 1.5 in
Bolt Length 3.75 in
Hardness Reading Scale C Scale
Hardness Reading Average 28.17
Spacing Ok