Print Report | Back to Sample Detail

Sample Record for 2024-03-13-36

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994591 DEA: 081J6704 EFIS: 0818000090 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-15-9.4/16.3
Work Description: MINOR CONCRETE, MODIFYING SIGNAL AND LIGHTING SYSTEMS, HMA AND JPCP.
Location Description: RIVERSIDE COUNTY IN MURRIETA AND WILDOMAR AT VARIOUS LOCATIONS FROM 0.1 MILE SOUTH OF MURRIETA HOT SPRINGS ROAD OVERCROSSING TO BUNDY CANYON ROAD UNDERCROSSING.
Contractor Name: BEADOR CONSTRUCTION COMPANY, INC.
Contractor Address: Unknown
Resident Engineer: Mike Bergevin Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-03-13-36
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 03/13/2024
Date that the sample was received by the laboratory/organization performing the testing: 03/18/2024
The quantity of what the sample constitutes: 2 BOXES OF HMA, 1 BAG OF RAP
A brief description of the sample: 3/4" HMA-A-SP R15 PG64-28M
From where was the sample collected: Manufacturer
Laboratory sample identification: 0139A-24
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AAA-Corona

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 105927

Test Results

Test 1 of 1

DIME Test ID: 2024-03-13-36-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 03/29/2024
Date Tested: 03/20/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 2150.2 g
Corrected Asphalt Binder Content 4.80 %
Mass Loss 107.7 g
Correction Factor (Percent by mass of HMA Specimen) 0.07 %
Moisture Content 0.00 %
Temperature Compensation Factor 0.14 %
Test Temperature 538 C