Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 209217 DEA: 080F5404 EFIS: 0800000136 COOP: 081468
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-91,15-0.0/13.04, 35.64/45.14
Work Description: SR-91 Corridor Improvement Project: Develop approx. 8 miles of tolled express lanes and related improvements within SR 91 between the Riverside/Orange County line and I-15, including transition areas.
Location Description: 08-RIV-91-0.0/13.04; 12-ORA-91-R14.43/R18.91; 08-RIV-15-35.64/45.14
Contractor Name: Atkinson Walsh, Joint Venture
Contractor Address: 1785 Sampson Ave, Corona, CA 92879
Resident Engineer: Richard Hebert Structure Rep.: Cyrus Shahinpar
DIME Sample ID: 2016-08-12-4
TL Number from the TL Form: C939846
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 08/12/2016
Date that the sample was received by the laboratory/organization performing the testing: 08/16/2016
The quantity of what the sample constitutes: 2
A brief description of the sample: Unknown
From where was the sample collected: Distributor
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Gerdau
Production or Authorization Testing: Production Testing
Threaded Bar Specification: ASTM A722
Threaded Bar Grade: 150
Threaded Bar Type:
Rebar Size: 1.25
Nut Specification for Threaded Bar: NA
System Manufacturer: DSI
Epoxy Coating Color: NA
Threaded Bar Application: Threaded Bar
Coating Standards: Uncoated
Bar Heat Number(s):
Nut Heat Number(s):
Bar Lot Number:
Nut Lot Number:
Coupler Heat Number(s):
Coupler Grade:
DIME Test ID: 2016-08-12-4-1
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Verified Date: 08/23/2016
Date Tested: 08/23/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: 1.25\" A722 Threaded Bar and Nut
Test Result Compliance:
Additional Comments When Verified:
Number of Threaded Bar Samples
|
1
|
Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Reduction of area (%) | Comments | Tested By | 2 | A722 DSI 1.250\" Threaded Bar & Nut | NA | 1.045 | 152936 | 133020 | 0 | 45.4 | 1.25\" A722 Threaded Bar and Nut | Brian |
| |
Temperature
|
72 F
|
UTM
|
400KIP
|
DIME Test ID: 2016-08-12-4-2
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Verified Date: 08/23/2016
Date Tested: 08/23/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: 1.25\" A722 Threaded Bar and Nut
Test Result Compliance:
Additional Comments When Verified:
Number of Threaded Bar Samples
|
1
|
Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Reduction of area (%) | Comments | Tested By | 2 | A722 DSI 1.250\" Threaded Bar & Nut | NA | 1.23 | 156711 | 128987 | 9 | 0 | 1.25\" A722 Threaded Bar and Nut | Brian |
| |
Temperature
|
72 F
|
UTM
|
400KIP
|