Print Report | Back to Sample Detail

Sample Record for 2024-03-01-17

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212112 DEA: 080C2514 EFIS: 0816000076 COOP: 081645 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-10-0.0/13.2
Work Description: Design-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location Description: LA/SBD County Line to PM 13.2 near I-15
Contractor Name: Lane-Security Paving Joint Venture
Contractor Address: 3450 Centre Lake Drive, 1st Floor, Ontario, CA 91761
Resident Engineer: Jose Corona Structure Rep.: Luis Negrete

Sample Information

DIME Sample ID: 2024-03-01-17
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 03/01/2024
Date that the sample was received by the laboratory/organization performing the testing: 03/04/2024
The quantity of what the sample constitutes: 80 drums
A brief description of the sample: 1 gallon can / PPC 1121 RESIN
From where was the sample collected: Source
Laboratory sample identification: 000044KBP
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers, Benicia

Material Information

Mfg. Lot Number(s): AZ4B00264D
Batch number: AZ4B00264D
Mix number: AZ4B00264D

Test Results

Test 1 of 6

DIME Test ID: 2024-03-01-17-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 05/13/2024
Date Tested: 04/10/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Viscosity 108

Test 2 of 6

DIME Test ID: 2024-03-01-17-2
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 05/13/2024
Date Tested: 04/10/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Density Units pounds/gallons
Liquid Density (pounds per gallon) 9

Test 3 of 6

DIME Test ID: 2024-03-01-17-3
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 05/13/2024
Date Tested: 03/06/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: Accepted Vendors Results
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested 6
Conditioning procedure 18/25/50+5/70
Speed of testing 0.45 in/min
Sample 1 Width 0.485 in
Sample 1 Ultimate strength 3860 psi
Sample 1 Thickness 0.268 in
Sample 1 Area 0.13 in^2
Sample 1 Ultimate Strength Actual 501.8 lbs
Sample 1 percent elongation 40.2 %
Sample 1 Time no data0 MM:SS
Sample 2 Width 0.485 in
Sample 2 Thickness 0.254 in
Sample 2 Area 0.1232 in^2
Sample 2 Ultimate strength 3996 psi
Sample 2 Ultimate Strength Actual 492.307 lbs
Sample 2 percent elongation 40.7 %
Sample 2 Time no data0 MM:SS
Sample 3 Width 0.486 in
Sample 3 Thickness 0.269 in
Sample 3 Area 0.1307 in^2
Sample 3 Ultimate strength 3904 psi
Sample 3 Ultimate Strength Actual 510.253 lbs
Sample 3 percent elongation 37.8 %
Sample 3 Time no data0 MM:SS
Sample 4 Width 0.484 in
Sample 4 Thickness 0.263 in
Sample 4 Area 0.1273 in^2
Sample 4 Ultimate strength 3886 psi
Sample 4 Ultimate Strength Actual 494.688 lbs
Sample 4 percent elongation 35.9 %
Sample 4 Time no data0 MM:SS
Sample 5 Width 0.485 in
Sample 5 Thickness 0.268 in
Sample 5 Area 0.13 in^2
Sample 5 Ultimate strength 3868 psi
Sample 5 Ultimate Strength Actual 502.84 lbs
Sample 5 percent elongation 39.7 %
Sample 5 Time no data0 MM:SS
Sample 6 Width 0.485 in
Sample 6 Thickness 0.266 in
Sample 6 Area 0.129 in^2
Sample 6 Ultimate strength 3897 psi
Sample 6 Ultimate Strength Actual 502.713 lbs
Sample 6 percent elongation 41.1 %
Sample 6 Time no data0 MM:SS
Ultimate Strength Average 3902 psi
Percent Elongation Average 39 %

Test 4 of 6

DIME Test ID: 2024-03-01-17-4
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 05/13/2024
Date Tested: 04/10/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Mean of two volatile content determination 44.9

Test 5 of 6

DIME Test ID: 2024-03-01-17-5
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Verified Date: 05/13/2024
Date Tested: 03/12/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: Accepted Vendors Results
Test Result Compliance: complies
Additional Comments When Verified:
Curing history for Sample 1 24hr
Maximum applied load (P) for Sample 1 1479 lb
Span length for Sample 1 9 in
Break location for Sample 1 bond
Specimen defects/notes for Sample 1 no data
Surface type for Sample 1 SSD
Modulus of rupture (R) for Sample 1 739.5 psi
Curing history for Sample 2 24hr
Maximum applied load (P) for Sample 2 1534.92 lb
Span length for Sample 2 9 in
Break location for Sample 2 bond
Specimen defects/notes for Sample 2 no data
Surface type for Sample 2 SSD
Modulus of rupture (R) for Sample 2 767.459 psi
Curing history for Sample 3 24hr
Maximum applied load (P) for Sample 3 1426.36 lb
Span length for Sample 3 9 in
Break location for Sample 3 bond
Specimen defects/notes for Sample 3 no data
Surface type for Sample 3 SSD
Modulus of rupture (R) for Sample 3 713.178 psi

Test 6 of 6

DIME Test ID: 2024-03-01-17-6
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 05/13/2024
Date Tested: 03/11/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: Accepted Vendors Results
Test Result Compliance: complies
Additional Comments When Verified:
Diameter of lid 153.9 mm
Room Temperature 78 f
Tare weight no data
Initial weight 100.081 grams
Weight at 5 minutes 99.98 grams
Weight at 10 minutes 99.887 grams
Weight at 15 minutes 99.823 grams
Weight at 20 minutes 99.758 grams
Weight at 25 minutes 99.686 grams
Weight at 30 minutes 99.569 grams
Final weight 99.57 grams
Total weight loss 0.51 grams
Calculated radius of gallon can lid in cm 7.695 cm
Lid Factor 53.757 m^2
Volatile emission 27.47 grams/m^2