Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994732 DEA: 043Q5004 EFIS: 0419000218
QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-580,980-Var
Work Description: POLYESTER CONCRETE OVERLAY, HMA (TYPE A), & SOIL DENSIFICATION.
Location Description: ALAMEDA COUNTY AT VARIOUS LOCATIONS
Contractor Name: MYERS & SONS CONSTRUCTION, LLC /Francisco Castillo
Contractor Address: Myers and Sons Construction, LLC 45 Morrison Ave., Sacramento, CA 95838
Resident Engineer: Jasmaninder (Jas) Singh Structure Rep.: Unknown
DIME Sample ID: 2024-02-29-37
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 02/29/2024
Date that the sample was received by the laboratory/organization performing the testing: 03/01/2024
The quantity of what the sample constitutes: 2 tankers
A brief description of the sample: 1 gallon can / PPC 1121 RESIN
From where was the sample collected: Source
Laboratory sample identification: 000039KBP
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers, Benicia
DIME Test ID: 2024-02-29-37-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 03/19/2024
Date Tested: 03/18/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
DIME Test ID: 2024-02-29-37-2
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 03/19/2024
Date Tested: 03/18/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Density Units
|
pounds/gallons
|
Liquid Density (pounds per gallon)
|
9
|
DIME Test ID: 2024-02-29-37-3
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 03/19/2024
Date Tested: 03/06/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted based on vendor's results.
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested
|
6
|
Conditioning procedure
|
18/25/50+5/70
|
Speed of testing
|
0.45 in/min
|
Sample 1 Width
|
0.485 in
|
Sample 1 Ultimate strength
|
3159.9 psi
|
Sample 1 Thickness
|
0.263 in
|
Sample 1 Area
|
0.1276 in^2
|
Sample 1 Ultimate Strength Actual
|
403.2 lbs
|
Sample 1 percent elongation
|
61.5 %
|
Sample 1 Time
|
0 MM:SS
|
Sample 2 Width
|
0.485 in
|
Sample 2 Thickness
|
0.272 in
|
Sample 2 Area
|
0.1319 in^2
|
Sample 2 Ultimate strength
|
3141 psi
|
Sample 2 Ultimate Strength Actual
|
414.3 lbs
|
Sample 2 percent elongation
|
60.5 %
|
Sample 2 Time
|
0 MM:SS
|
Sample 3 Width
|
0.484 in
|
Sample 3 Thickness
|
0.253 in
|
Sample 3 Area
|
0.1225 in^2
|
Sample 3 Ultimate strength
|
3195.1 psi
|
Sample 3 Ultimate Strength Actual
|
391.4 lbs
|
Sample 3 percent elongation
|
56.7 %
|
Sample 3 Time
|
0 MM:SS
|
Sample 4 Width
|
0.486 in
|
Sample 4 Thickness
|
0.254 in
|
Sample 4 Area
|
0.1234 in^2
|
Sample 4 Ultimate strength
|
3188.8 psi
|
Sample 4 Ultimate Strength Actual
|
393.5 lbs
|
Sample 4 percent elongation
|
52.9 %
|
Sample 4 Time
|
0 MM:SS
|
Sample 5 Width
|
0.485 in
|
Sample 5 Thickness
|
0.263 in
|
Sample 5 Area
|
0.1276 in^2
|
Sample 5 Ultimate strength
|
3155.2 psi
|
Sample 5 Ultimate Strength Actual
|
402.6 lbs
|
Sample 5 percent elongation
|
62.8 %
|
Sample 5 Time
|
0 MM:SS
|
Sample 6 Width
|
0.486 in
|
Sample 6 Thickness
|
0.26 in
|
Sample 6 Area
|
0.1264 in^2
|
Sample 6 Ultimate strength
|
3174.8 psi
|
Sample 6 Ultimate Strength Actual
|
401.3 lbs
|
Sample 6 percent elongation
|
60.4 %
|
Sample 6 Time
|
0 MM:SS
|
Ultimate Strength Average
|
3169 psi
|
Percent Elongation Average
|
59 %
|
DIME Test ID: 2024-02-29-37-4
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 03/19/2024
Date Tested: 03/18/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Mean of two volatile content determination
|
45
|
DIME Test ID: 2024-02-29-37-5
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Verified Date: 03/19/2024
Date Tested: 03/12/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted based on vendor's results
Test Result Compliance: complies
Additional Comments When Verified:
Curing history for Sample 1
|
24hr
|
Maximum applied load (P) for Sample 1
|
1334 lb
|
Span length for Sample 1
|
9 in
|
Break location for Sample 1
|
bond
|
Specimen defects/notes for Sample 1
|
no data
|
Surface type for Sample 1
|
SSD
|
Modulus of rupture (R) for Sample 1
|
667 psi
|
Curing history for Sample 2
|
24hr
|
Maximum applied load (P) for Sample 2
|
1102 lb
|
Span length for Sample 2
|
9 in
|
Break location for Sample 2
|
bond
|
Specimen defects/notes for Sample 2
|
no data
|
Surface type for Sample 2
|
SSD
|
Modulus of rupture (R) for Sample 2
|
551 psi
|
Curing history for Sample 3
|
24hr
|
Maximum applied load (P) for Sample 3
|
1020 lb
|
Span length for Sample 3
|
9 in
|
Break location for Sample 3
|
bond
|
Specimen defects/notes for Sample 3
|
no data
|
Surface type for Sample 3
|
SSD
|
Modulus of rupture (R) for Sample 3
|
510 psi
|
DIME Test ID: 2024-02-29-37-6
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 03/19/2024
Date Tested: 03/11/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted based on vendor's results
Test Result Compliance: complies
Additional Comments When Verified:
Diameter of lid
|
153.9 mm
|
Room Temperature
|
78 f
|
Tare weight
|
no data
|
Initial weight
|
100.121 grams
|
Weight at 5 minutes
|
99.99 grams
|
Weight at 10 minutes
|
99.888 grams
|
Weight at 15 minutes
|
99.76 grams
|
Weight at 20 minutes
|
99.596 grams
|
Weight at 25 minutes
|
99.5 grams
|
Weight at 30 minutes
|
99.391 grams
|
Final weight
|
99.39 grams
|
Total weight loss
|
0.73 grams
|
Calculated radius of gallon can lid in cm
|
7.695 cm
|
Lid Factor
|
53.757 m^2
|
Volatile emission
|
39.296 grams/m^2
|