Print Report | Back to Sample Detail

Sample Record for 2024-03-08-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994535 DEA: 010H8404 EFIS: 0118000117 QA Service Level: 1
DIST-CO-RTE-PM: 01-LAK-20-2.0/2.8
Work Description: RDWY EXC, PLACE HMA-A & RHMA, CONST SOLDIER PILE & RETAINING WALLS.
Location Description: LAKE COUNTY ABOUT 6 MILES WEST OF UPPER LAKE FROM 0.6 MILE WEST OF IRVINE AVENUE TO 0.1 MILE EAST OF MID LAKE ROAD
Contractor Name: GHILOTTI CONSTRUCTION COMPANY, INC.
Contractor Address: Unknown
Resident Engineer: Dan Kraft Structure Rep.: Hayden Terrill

Sample Information

DIME Sample ID: 2024-03-08-1
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 03/08/2024
Date that the sample was received by the laboratory/organization performing the testing: 03/18/2024
The quantity of what the sample constitutes: 32
A brief description of the sample: ASTM A615 Grade 80 Bare Size 14 rebar
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Nucor Skyline Steel

Material Information

Production or Authorization Testing: Production Testing
Threaded Bar Specification: ASTM A615
Threaded Bar Grade: 80
Threaded Bar Type: Deformed
Rebar Size: #14
Nut Specification for Threaded Bar: ASTM A576 Grade 1045
System Manufacturer: Nucor Skyline
Epoxy Coating Color: NA
Threaded Bar Application: Soil Nail
Coating Standards: Uncoated
Bar Heat Number(s): 3700035351
Nut Heat Number(s): 58048414
Bar Lot Number: 37000353120, 37000353121
Nut Lot Number: W83566, W83559
Coupler Heat Number(s): NA
Coupler Grade: NA

Test Results

Test 1 of 2

DIME Test ID: 2024-03-08-1-1
Test Method: ASTM A615-20: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 03/22/2024
Date Tested: 03/19/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A615 Bar and Nut
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
No.14/43mm2.251218919399015.51A615 Bar and Nutaauvinen
Temperature 72 f
UTM 400kip

Test 2 of 2

DIME Test ID: 2024-03-08-1-2
Test Method: ASTM A615-20: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 03/22/2024
Date Tested: 03/19/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A615 Nut
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
No.14/43mm2.25121959920950A615 Nutaauvinen
Temperature 72 f
UTM 400kip