Project Information

Project ID: 209921 DEA: 073X8204 EFIS: 0713000218 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-39-21.7,22.0
Work Description: REPAIR SLOPE FAILURE.
Location Description: LOS ANGELES COUNTY AT 0.2 MILE NORTH OF CARPENTER CANYON BRIDGE AND AT 0.2 MILE SOUTH OF PEJSA CANYON BRIDGE
Contractor Name: CHUMO CONSTRUCTION INC
Contractor Address: 14425 JOANBRIDGE STREET, BALDWIN PARK CA 91706
Resident Engineer: Micheal Chou Structure Rep.: Cardiel O Bugarin

Sample Information

DIME Sample ID: 2016-08-09-6
TL Number from the TL Form: No 2
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 08/09/2016
Date that the sample was received by the laboratory/organization performing the testing: 08/12/2016
The quantity of what the sample constitutes: 4
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 938-08
Structure unique identifier: RTE 39 MOMENT SLAB
Structure name: RTE 39 MOMENT SLAB
The fabricator/manufacturer/facility name: ROBERTSONS

Material Information

The concrete mix design number: SC675B38
The truck number from where the sample was collected: 1567
The batch plant ticket number from where the sample was collected: 2251134
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: PLANT
A detailed description of where the material sample was collected: TRUCK
Where the material sample would have been placed if not sampled: LOCATION 2 RTE 39 MOMENT SLAB
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Results

Test 1 of 2

DIME Test ID: 2016-08-09-6-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/15/2016
Date Tested: 08/12/2016
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 6.01 in
Average diameter of cylinder 2 6.01 in
Cross sectional area of cylinder 1 28.37 in^2
Cross sectional area of cylinder 2 28.37 in^2
Compressive strength (to nearest 10 psi) 2030 psi
Maximum load on cylinder 1 58430 lb
Maximum load on cylinder 2 56870 lb
Compressive strength of cylinder 1 2059.6 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 2004.6 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 no data
Age of specimen 3 days
Age of specimen in hours no data

Test 2 of 2

DIME Test ID: 2016-08-09-6-2
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 09/06/2016
Date Tested: 09/06/2016
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 6.02 in
Average diameter of cylinder 2 6.02 in
Cross sectional area of cylinder 1 28.46 in^2
Cross sectional area of cylinder 2 28.46 in^2
Compressive strength (to nearest 10 psi) 3960 psi
Maximum load on cylinder 1 112160 lb
Maximum load on cylinder 2 113270 lb
Compressive strength of cylinder 1 3941.0 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 3980.0 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 no data
Age of specimen 28 days
Age of specimen in hours no data