Print Report | Back to Sample Detail

Sample Record for 2024-02-29-16

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994214 DEA: 07337904 EFIS: 0717000052 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-2,10,101,134-Var
Work Description: MODIFY CAMERA, MESSAGE SIGN & RM SYSTEMS, & REPLACE SIGN STRUCTURES.
Location Description: IN LOS ANGELES COUNTY AT VARIOUS LOCATIONS.
Contractor Name: SELECT ELECTRIC INC.
Contractor Address: Unknown
Resident Engineer: KRIS VENKATARAMAN Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-02-29-16
TL Number from the TL Form:
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Acceptance
Type of Material: Soil
Sample Taken Date: 02/29/2024
Date that the sample was received by the laboratory/organization performing the testing: 02/29/2024
The quantity of what the sample constitutes: 103 cy
A brief description of the sample: Subgrade
From where was the sample collected: Job Site
Laboratory sample identification: 24-0378
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: I.E. Engineering

Material Information

The fabricator's/manufacturer's product name for the sample: Subgrade
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: From various locations at subgrade
Where the material sample would have been placed if not sampled:

Test Results

Test 1 of 2

DIME Test ID: 2024-02-29-16-1
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Verified Date: 03/07/2024
Date Tested: 02/29/2024
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
Standard Count Density 2061 g/cc
Count or Density 1 1144 g/cc
Count or Density 2 1147 g/cc
Count or Density 3 1112 g/cc
Standard Count Moisture 665 g/cc
Moisture Count 1 125 g/cc
Moisture Count 2 157 g/cc
Moisture Count 3 125 g/cc
Sum of Count or Density 3403.00 g/cc
Average of Count or Density 1134.00 g/cc
Sum of Moisture Count 407.00 g/cc
Average of Moisture Count 136.00 g/cc
Count Ratio Density 0.55
Count Ratio Moisture 0.20
Calculated Percent Relative Compaction 89.6 %
Reported Percent Relative Compaction 90 %

Test 2 of 2

DIME Test ID: 2024-02-29-16-2
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Verified Date: 03/07/2024
Date Tested: 02/29/2024
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
Is oversize material No
In-place wet density 1.90
Highest adjust wet density 2.12
Relative compaction 90
% Moisture no data
Optimum Moisture no data