Project Information

Project ID: 210887 DEA: 07243204 EFIS: 0714000274 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-5-39.4/R88.6
Work Description: REPLACE OVERHEAD SIGN PANELS TO TYPE XI RETROREFLECTIVE SIGNS.
Location Description: IN LOS ANGELES COUNTY, BETWEEN SR-170 AND KERN COUNTY LINE
Contractor Name: C&W Construction Specialties
Contractor Address: 2419 Palma Drive , Ventura, CA 93003
Resident Engineer: RIDWAN SALMAN Structure Rep.: David Bar-On

Sample Information

DIME Sample ID: 2016-07-24-1
TL Number from the TL Form: 940-01
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 07/24/2016
Date that the sample was received by the laboratory/organization performing the testing: 08/01/2016
The quantity of what the sample constitutes: 4
A brief description of the sample: Concrete Cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 940-01
Structure unique identifier: Unknown
Structure name: Unknown
The fabricator/manufacturer/facility name: National

Material Information

The concrete mix design number: s63061
The truck number from where the sample was collected: 2
The batch plant ticket number from where the sample was collected: 703446
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: Site
Where the material sample would have been placed if not sampled: CIDH Pile for Sign Str
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Results

Test 1 of 2

DIME Test ID: 2016-07-24-1-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/08/2016
Date Tested: 08/08/2016
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.01 in
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.37 in^2
Compressive strength (to nearest 10 psi) 3780 psi
Maximum load on cylinder 1 106370 lb
Maximum load on cylinder 2 107810 lb
Compressive strength of cylinder 1 3762.6 psi
Type of fracture pattern of cylinder 1 1
Compressive strength of cylinder 2 3800.1 psi
Type of fracture pattern of cylinder 2 4
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 no data
Age of specimen 15 days
Age of specimen in hours no data

Test 2 of 2

DIME Test ID: 2016-07-24-1-2
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/23/2016
Date Tested: 08/22/2016
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 6.01 in
Average diameter of cylinder 2 6.01 in
Cross sectional area of cylinder 1 28.37 in^2
Cross sectional area of cylinder 2 28.37 in^2
Compressive strength (to nearest 10 psi) 4240 psi
Maximum load on cylinder 1 119070 lb
Maximum load on cylinder 2 121340 lb
Compressive strength of cylinder 1 4197.0 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 4277.1 psi
Type of fracture pattern of cylinder 2 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 no data
Age of specimen 29 days
Age of specimen in hours no data