Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 8196 DEA: 59912684
QA Service Level: 1
DIST-CO-RTE-PM: 59---
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2016-07-25-14
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 07/25/2016
Date that the sample was received by the laboratory/organization performing the testing: 08/02/2016
The quantity of what the sample constitutes: 6
A brief description of the sample: Prestressing Strand
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Insteel Stressteel
Comments: Unknown
Reel/Coil/Pack Number(s):
Number of Coils: Unknown
Group Number: Unknown
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): 16101908
Mfg. Lot Number(s): NA
Manufacturer(s): Insteel Stressteel
DIME Test ID: 2016-07-25-14-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 08/05/2016
Date Tested: 08/04/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | 16101908 | 1302466153443 | 0.217 | 60856 | 55471 | 28.4 | 1.75 | Brian |
| |
UTM
|
120KIP
|
Temperature
|
74 F
|
Extensometers
|
E88766
|
DIME Test ID: 2016-07-25-14-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 08/05/2016
Date Tested: 08/04/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | 16101908 | 1302466153451 | 0.217 | 61048 | 55398 | 28.3 | 1.73 | Brian |
| |
UTM
|
120KIP
|
Temperature
|
74 F
|
Extensometers
|
E88766
|