Sample Record for 2024-01-27-3
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 994109 DEA: 060W1704 EFIS: 0617000103
QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-41-R27.4/R28.5
Work Description: REMOVE AC PAVEMENT, WIDEN TRAVEL WAY, AND CONSTRUCT RETAINING WALL.
Location Description: FRESNO COUNTY IN FRESNO FROM 0.1 MILE SOUTH OF ASHLAN AVENUE OVERCROSSING TO SHAW AVENUE OVERCROSSING
Contractor Name: RNR Construction, Inc
Contractor Address: 8589 Thys Court, Sacramento, CA,95828
Resident Engineer: Mark Mengoni Structure Rep.: Benjamin Holton
Sample Information
DIME Sample ID: 2024-01-27-3
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Millbrook Field Laboratory
Sample Organization Contact: (559) 417-5341
Type of Sample: Department Acceptance
Type of Material: Concrete
Sample Taken Date: 01/27/2024
Date that the sample was received by the laboratory/organization performing the testing: 01/28/2024
The quantity of what the sample constitutes: 6 4x8 Cylinders
A brief description of the sample: 4x8 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: RNR Construction
Material Information
The concrete mix design number: ND22023
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 111236809
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: wall 3
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 1
DIME Test ID: 2024-01-27-3-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 02/26/2024
Date Tested: 02/26/2024
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 3240 North Millbrook Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93726
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
3
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
Average diameter of cylinder 1
|
3.99 in
|
Average diameter of cylinder 2
|
3.99 in
|
Average diameter of cylinder 3
|
4.00 in
|
Cross sectional area of cylinder 1
|
12.5 in^2
|
Cross sectional area of cylinder 2
|
12.5 in^2
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
Compressive strength (to nearest 10 psi)
|
5800 psi
|
Maximum load on cylinder 1
|
71250 lb
|
Maximum load on cylinder 2
|
73960 lb
|
Maximum load on cylinder 3
|
72870 lb
|
Compressive strength of cylinder 1
|
5700.0 psi
|
Type of fracture pattern of cylinder 1
|
2
|
Compressive strength of cylinder 2
|
5916.8 psi
|
Compressive strength of cylinder 3
|
5797.1 psi
|
Type of fracture pattern of cylinder 2
|
2
|
Type of fracture pattern of cylinder 3
|
2
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Correction factor for cylinder 3
|
1
|
Age of specimen
|
30 days
|
Age of specimen in hours
|
0 hours
|