Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 042G9404 Cty NAP Rte 128 PM 17.9 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Danilo Patenia |
Date Reported: |
08/04/2016 |
|
Address: |
TL Number: |
209654 |
||
City: |
||||
Project Name: CONSTRUCT ROADWAY RETAINING SYSTEM |
||||
Prime Contractor: GORDON N BALL INC |
||||
Sample Taken Date: |
08/01/2016 |
Mix Design: |
5834a25 |
|
Contractor: Unknown |
Location: NAPA COUNTY AT 1.1 MILES WEST OF KNOXVILLE ROAD |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 5.97 | 27.99 | 42306 | 1511.5 | 1 |
2 | 5.98 | 28.09 | 42545 | 1514.6 | 1 |
DIME Test ID: 2016-08-01-3-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 1510
Age of specimen: 3 days
Certified By: Mike Mullins
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing