Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 034E8604 Cty PLA Rte 193 PM 4.4/5.5 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Brahim Oulad-Daoud |
Date Reported: |
08/01/2016 |
|
Address: |
TL Number: |
199722 |
||
City: |
||||
Project Name: CURVE IMPROVEMENT |
||||
Prime Contractor: A. TEICHERT & SON, INC. DBA TEICHERT CONSTRUCTION |
||||
Sample Taken Date: |
07/25/2016 |
Mix Design: |
toh6040cc |
|
Contractor: Unknown |
Location: PLACER COUNTY NEAR LINCOLN FROM 0.1 MILE WEST TO 1.0 MILE EAST OF CLARK TUNNEL ROAD |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.01 | 28.37 | 94971 | 3347.6 | 1 |
2 | 6.00 | 28.27 | 90608 | 3205.1 | 1 |
DIME Test ID: 2016-07-25-3-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 3280
Age of specimen: 7 days
Certified By: Mike Mullins
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing