Print Report | Back to Sample Detail

Sample Record for 2024-01-30-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994245 DEA: 051H4304 EFIS: 0516000073 QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-101-21.4/21.9
Work Description: REPLACE STRUCTURAL CONCRETE BRIDGES.
Location Description: SANTA BARBARA COUNTY IN GOLETA FROM ROUTE 101/217 SEPARATION TO 0.3 MILE NORTH OF SAN JOSE CREEK BRIDGE
Contractor Name: MCM CONSTRUCTION
Contractor Address: 6413 32nd Street, North Highlands, Ca 95660
Resident Engineer: Manny Yogarajah Structure Rep.: Fabian Velasco

Sample Information

DIME Sample ID: 2024-01-30-2
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 01/30/2024
Date that the sample was received by the laboratory/organization performing the testing: 02/08/2024
The quantity of what the sample constitutes: 15 Threaded Bars
A brief description of the sample: 1 1/4" 150 ksi all thread bar
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Williams Form Engineering San Diego

Material Information

Production or Authorization Testing: Production Testing
Threaded Bar Specification: ASTM A722
Threaded Bar Grade: 722
Threaded Bar Type: Deformed
Rebar Size: #10
Nut Specification for Threaded Bar: ASTM E112 Grade 1045
System Manufacturer: Williams Form Enginerring
Epoxy Coating Color: NA
Threaded Bar Application: Threaded Bar
Coating Standards: Uncoated
Bar Heat Number(s): 58055774/04
Nut Heat Number(s): n/a
Bar Lot Number: Lot 1-04
Nut Lot Number: n/a
Coupler Heat Number(s): N/A
Coupler Grade: n/a

Test Results

Test 1 of 2

DIME Test ID: 2024-01-30-2-1
Test Method: ASTM A722-18: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Verified Date: 02/09/2024
Date Tested: 02/09/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A722 Bar - Reduction of Area
Test Result Compliance:
Additional Comments When Verified:
Number of Threaded Bar Samples 1
SampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
1ASTM A722 Type II Deformed Bar 1 1/4 : 32mm580557741.204166117142.71029.2A722 Bar - Reduction of Areaaauvinen
Temperature 72 f
UTM 400kip

Test 2 of 2

DIME Test ID: 2024-01-30-2-2
Test Method: ASTM A722-18: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Verified Date: 02/09/2024
Date Tested: 02/09/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A722 Bar - Elongation and Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Threaded Bar Samples 1
SampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
2ASTM A722 Type II Deformed Bar 1 1/4 : 32mm580557741.25174149140.858100A722 Bar - Elongation and Tensileaauvinen
Temperature 72 f
UTM 400kip