Print Report | Back to Sample Detail

Sample Record for 2024-01-16-31

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994712 DEA: 051Q6804 EFIS: 0523000063 QA Service Level: 1
DIST-CO-RTE-PM: 05-SB,SB/SB-154-2/31.5
Work Description:
Location Description:
Contractor Name: CalPortland Construction
Contractor Address: Unknown
Resident Engineer: Jaime Engler Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-01-16-31
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - Buellton Field Laboratory
Sample Organization Contact:
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 01/16/2024
Date that the sample was received by the laboratory/organization performing the testing: 01/16/2024
The quantity of what the sample constitutes: 378 tons
A brief description of the sample: CPC Garey: 3/4" HMA-A
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CalPortland Garey Hot Plant

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number: 1
Sublot number: 1
HMA Mix Number: D1321F215

Test Results

Test 1 of 1

DIME Test ID: 2024-01-16-31-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 01/22/2024
Date Tested: 01/22/2024
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: glenn.johnson@dot.ca.gov
Organization Phone: (805) 549-3158
General Comments for this Test: right oven
Test Result Compliance: does not comply
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 2091.1 g
Corrected Asphalt Binder Content 4.7 %
Mass Loss 117.7 g
Correction Factor (Percent by mass of HMA Specimen) 0.93 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 482 C