Print Report | Back to Sample Detail

Sample Record for 2024-01-11-8

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994267 DEA: 07326204 EFIS: 0716000113 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-39-17.8
Work Description: CONSTRUCT BRIDGE, PLACE STRUCTURAL STEEL AND CONCRETE BARRIER.
Location Description: LOS ANGELES COUNTY IN AZUSA AT SAN GABRIEL RIVER BRIDGE
Contractor Name: FEC Future Contractors & Engineers, Inc
Contractor Address: 184 Technology Dr., Ste 2, Irvine, CA 92618
Resident Engineer: Joe Doughly Structure Rep.: Hadi Moradi

Sample Information

DIME Sample ID: 2024-01-11-8
TL Number from the TL Form:
Sample Submitted By Organization: CT - Unassigned/General Field Laboratory
Sample Organization Contact: 5625005861
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 01/11/2024
Date that the sample was received by the laboratory/organization performing the testing: 01/18/2024
The quantity of what the sample constitutes: Various
A brief description of the sample: A325 HDG
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cordova Bolt

Material Information

Rocap Number(s): 76829-3
Heat Number(s): 3121459, 8000010207, 128064
Nut Mfg. Lot Number(s): 459484A
Washer Mfg. Lot Number(s): 0123-596
Bolt Specification: A325
Bolt Length(s): 33"
Nut Specification: A563
Washer Specification: F436
Finish: HDG
Diameter/Size: 1 1/2"
Bolt Mfg. Lot Number: 76829-3
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Results

Test 1 of 9

DIME Test ID: 2024-01-11-8-1
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 01/31/2024
Date Tested: 01/18/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Proof Load
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
1A223918Proof Load
UTM 450kip
Temperature 72 f

Test 2 of 9

DIME Test ID: 2024-01-11-8-2
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 01/31/2024
Date Tested: 01/19/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
176829-30.4990.1968940412818017.7rmacias
UTM 67kip
Temperature 72 f

Test 3 of 9

DIME Test ID: 2024-01-11-8-3
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 01/31/2024
Date Tested: 01/19/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
276829-30.4990.1968863112757917.4
UTM 67kip
Temperature 72 f

Test 4 of 9

DIME Test ID: 2024-01-11-8-4
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 01/31/2024
Date Tested: 01/19/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 76829-3
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325 55
Size 1.5 in
Bolt Length 33 in
Gage Type Pass

Test 5 of 9

DIME Test ID: 2024-01-11-8-5
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 01/31/2024
Date Tested: 01/19/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 459484A
Finish Coating ASTM F2329 - Hot Dip
Product Markings DH N
Size 1.5 in
Gage Type Pass

Test 6 of 9

DIME Test ID: 2024-01-11-8-6
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/31/2024
Date Tested: 01/19/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) 76829-3
Mfg. Lot Number no data
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325 55
Size 1.5 in
Bolt Length 33 in
Measurement Average 4.28 mils

Test 7 of 9

DIME Test ID: 2024-01-11-8-7
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/31/2024
Date Tested: 01/19/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 459484A
Finish Coating ASTM F2329 - Hot Dip
Product Markings DH N
Size 1.5 in
Bolt Length no data in
Measurement Average 2.8 mils

Test 8 of 9

DIME Test ID: 2024-01-11-8-8
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 01/31/2024
Date Tested: 01/19/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 0123-596
Finish Coating ASTM F2329 - Hot Dip
Product Markings TSI F436
Size 1.5 in
Bolt Length no data in
Measurement Average 2.64 mils

Test 9 of 9

DIME Test ID: 2024-01-11-8-9
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 01/31/2024
Date Tested: 01/19/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 0123-596
Finish Coating ASTM F2329 - Hot Dip
Product Markings TSI F436
Size 1.5 in
Bolt Length no data in
Hardness Reading Scale B Scale
Hardness Reading Average 39.75
Spacing Ok