Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 212246 DEA: 053307A4 EFIS: 0514000027
QA Service Level: 1
DIST-CO-RTE-PM: 05-SLO-46-49.7/54.6
Work Description: Cholame Segment
Location Description:
Contractor Name: Atkinson Construction
Contractor Address: 18201 Von Karman - Suite 800, Irvine, CA 92612
Resident Engineer: Andrew Borrelli Structure Rep.: Dave Lewis
DIME Sample ID: 2023-11-01-118
TL Number from the TL Form: C979513
Sample Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Dispute Resolution
Type of Material: Hot Mix Asphalt
Sample Taken Date: 11/01/2023
Date that the sample was received by the laboratory/organization performing the testing: 01/05/2024
The quantity of what the sample constitutes: 2 Boxes of HMA 1 Core
A brief description of the sample: 3/4" HMA-A w/15% RAP, WMA
From where was the sample collected: Job Site
Laboratory sample identification: 024-003
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: SPM AVENAL
DIME Test ID: 2023-11-01-118-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 01/08/2024
Date Tested: 01/08/2024
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of tests
|
2
|
What is the unit of measurement for theoretical density?
|
SI Units
|
Mass Determination
|
Water
|
Method Performed
|
Mechanical Agitation - Method A
|
Mass of oven-dry sample in air for Sample 1
|
2539.6 grams
|
Mass of sample in water for Sample 1
|
1503.7 grams
|
Mass of oven-dry sample in air for Sample 2
|
2611.6 grams
|
Mass of sample in water for Sample 2
|
1548.1 grams
|
Temperature of Water
|
77 °F
|
Specific Gravity for Sample 1
|
2.452
|
Specific Gravity for Sample 2
|
2.456
|
Average Specific Gravity
|
2.454
|
Theoretical maximum density at 25°C (77°F)
|
2446.9 kg/m^3
|
DIME Test ID: 2023-11-01-118-2
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 01/08/2024
Date Tested: 01/08/2024
Submitted By Organization: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Organization Address: 5900 Folsom Boulevard, Room 225,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (916) 227-7302
General Comments for this Test: Core L3SL5A
Test Result Compliance:
Additional Comments When Verified:
Bulk Specific Gravity
|
2.206
|