Print Report | Back to Sample Detail

Sample Record for 2023-08-30-100

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993529 DEA: 11430514 EFIS: 1119000008 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-15-R31.3/R37.1
Work Description: CRCP, FIBER OPTIC CABLE, AND HMA.
Location Description: SAN DIEGO COUNTY IN AND NEAR ESCONDIDO FROM 0.2 MILE SOUTH OF ROUTE 15/78 SEPARATION TO 0.5 MILE NORTH OF DEER SPRINGS ROAD OVERCROSSING
Contractor Name: Security Paving Company, Inc.
Contractor Address: 13170 Telfair Ave, Sylmar, CA 91342
Resident Engineer: Jason Alsheikh Structure Rep.: Tan Cao

Sample Information

DIME Sample ID: 2023-08-30-100
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 688-1570
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/30/2023
Date that the sample was received by the laboratory/organization performing the testing: 09/01/2023
The quantity of what the sample constitutes: 4 boxes 2 bags
A brief description of the sample: 3/4 HMA-A
From where was the sample collected: Job Site
Laboratory sample identification: 6630-A
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marietta

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number:

Test Results

Test 1 of 4

DIME Test ID: 2023-08-30-100-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 03/19/2024
Date Tested: 10/25/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 1 7477.1 grams
Mass of oven-dry sample in air for Sample 1 2561.4 grams
Mass of container filled with the sample and water for Sample 1 9000.8 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.468
Theoretical maximum density at 25°C (77°F) 153.6 lb/ft^3

Test 2 of 4

DIME Test ID: 2023-08-30-100-2
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 03/19/2024
Date Tested: 10/25/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test: Complies T-209 RAP
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 1 7477.1 grams
Mass of oven-dry sample in air for Sample 1 1560.4 grams
Mass of container filled with the sample and water for Sample 1 8399.5 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.446
Theoretical maximum density at 25°C (77°F) 152.3 lb/ft^3

Test 3 of 4

DIME Test ID: 2023-08-30-100-3
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 03/19/2024
Date Tested: 10/26/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test: Complies T308 RAP 1 Use this RAP for Dime
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 3930.1 g
Mass of the specimen and specimen basket assembly prior to ignition 5577.2 g
Mass of HMA Sample prior to ignition 1647.1 g
Corrected Asphalt Binder Content 6.87 %
Mass Loss 113.2 g
Mass of aggregate remaining after ignition 1533.9 g
Correction Factor (Percent by mass of HMA Specimen) 0.00 %
Moisture Content 0.00 %
Temperature Compensation Factor 0.00 %
Test Temperature 538 C

Test 4 of 4

DIME Test ID: 2023-08-30-100-6
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 03/19/2024
Date Tested: 10/26/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test: Complies Target 5.0 / -.3 to +.5 - Results - 5.35 %
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 3974.7 g
Mass of the specimen and specimen basket assembly prior to ignition 5992.3 g
Mass of HMA Sample prior to ignition 2017.6 g
Corrected Asphalt Binder Content 5.35 %
Mass Loss 117.8 g
Mass of aggregate remaining after ignition 1899.8 g
Correction Factor (Percent by mass of HMA Specimen) 0.49 %
Moisture Content 0.00 %
Temperature Compensation Factor 0.00 %
Test Temperature 538 C