Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 993815 DEA: 081C0814 EFIS: 0816000086
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-10-R60.7/R74.3
Work Description: I-10 PAVEMENT REHABILITATION (SEGMENT 1) PROJECT
Location Description: Coachella
Contractor Name: COFFMAN SPECIALTIES, INC
Contractor Address: 4375 JUTLAND DRIVE STE 260, SAN DIEGO CA 92117
Resident Engineer: Michael Sergah Structure Rep.: Al Alina
DIME Sample ID: 2023-10-13-90
TL Number from the TL Form:
Sample Submitted By Organization: Sequoia Consultants
Sample Organization Contact: (714) 974-6316
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 10/13/2023
Date that the sample was received by the laboratory/organization performing the testing: 10/13/2023
The quantity of what the sample constitutes: 4 samples
A brief description of the sample: Paving Concrete (JPCP)
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Coffman Specialties, Inc
The concrete mix design number: 2201-2
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: NA
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: On site batch plant
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2023-10-13-90-1
Test Method: AASHTO T336-15: Standard Method of Test for Coefficient of Thermal Expansion of Hydraulic Cement Concrete
Verified Date: 01/05/2024
Date Tested: 11/16/2023
Submitted By Organization: Sequoia Consultants
Organization Address: 361 West Grove Avenue,
Organization City: Orange
Organization State: CA
Organization Zipcode: 92865
Organization Email: sranjan@sequoiacon.com
Organization Phone: 1 (714) 974-6316
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Average CTE
|
0.000006669 mm/mm/°C
|
Average CTE
|
3.705E-6 in/in/°F
|
DIME Test ID: 2023-10-13-90-2
Test Method: AASHTO T336-15: Standard Method of Test for Coefficient of Thermal Expansion of Hydraulic Cement Concrete
Verified Date: 01/05/2024
Date Tested: 11/16/2023
Submitted By Organization: Sequoia Consultants
Organization Address: 361 West Grove Avenue,
Organization City: Orange
Organization State: CA
Organization Zipcode: 92865
Organization Email: sranjan@sequoiacon.com
Organization Phone: 1 (714) 974-6316
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Average CTE
|
0.000007751 mm/mm/°C
|
Average CTE
|
4.306E-6 in/in/°F
|
DIME Test ID: 2023-10-13-90-3
Test Method: AASHTO T336-15: Standard Method of Test for Coefficient of Thermal Expansion of Hydraulic Cement Concrete
Verified Date: 01/05/2024
Date Tested: 11/17/2023
Submitted By Organization: Sequoia Consultants
Organization Address: 361 West Grove Avenue,
Organization City: Orange
Organization State: CA
Organization Zipcode: 92865
Organization Email: sranjan@sequoiacon.com
Organization Phone: 1 (714) 974-6316
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Average CTE
|
0.000006891 mm/mm/°C
|
Average CTE
|
3.829E-6 in/in/°F
|
DIME Test ID: 2023-10-13-90-4
Test Method: AASHTO T336-15: Standard Method of Test for Coefficient of Thermal Expansion of Hydraulic Cement Concrete
Verified Date: 01/05/2024
Date Tested: 11/17/2023
Submitted By Organization: Sequoia Consultants
Organization Address: 361 West Grove Avenue,
Organization City: Orange
Organization State: CA
Organization Zipcode: 92865
Organization Email: sranjan@sequoiacon.com
Organization Phone: 1 (714) 974-6316
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Average CTE
|
0.000007639 mm/mm/°C
|
Average CTE
|
4.244E-6 in/in/°F
|